How a Swagelok tube fitting part number is built — material prefix, tube size in sixteenths or metric with the M, body style digits, end connection — decoded against worked examples (SS-400-6, SS-6M0-1-4, SS-810-1-8), the two-ferrule principle and why single-ferrule copies fail, fractional and metric size tables with wall-thickness limits, pull-up practice (1-1/4 turns, gap gauge, retightening), mixing rules between makers, and the adjacent valve and gauge programme.
| Segment | Codes | Notes |
|---|---|---|
| Material prefix | SS = 316 SS; B = brass; S = carbon steel; M = Monel; HC = Hastelloy C; T/PFA = polymer lines | First block before the dash |
| Tube size | Sixteenths: 2, 4, 6, 8, 10, 12, 16; metric: 3M, 6M, 8M, 10M, 12M, 18M, 25M | The number the wrench size follows |
| Body style | 0 after metric size (6M0) marks the metric series; then -1 male connector, -2 female connector(by family), -3 union tee, -4 cross (as 4-way), -6 union, -7 female connector, -9 union elbow, -P plug, -C cap, -R reducer | The style digits are the fitting's function |
| End connection | -2 = 1/8 NPT, -4 = 1/4 NPT, -6 = 3/8 NPT, -8 = 1/2 NPT (on connector styles); RT suffixes for BSPT, RS/RP for parallel BSP variants | Second size block on connectors |
| Worked example | Reads as |
|---|---|
| SS-400-6 | 316 SS, 1/4 in. tube union |
| SS-810-3 | 316 SS, 1/2 in. tube union tee (e.g. the SS-1610-3 is the 1 in. big brother) |
| SS-6M0-1-4 | 316 SS, 6 mm tube, male connector, 1/4 in. NPT |
| SS-1610-P | 316 SS plug for a 1 in. tube fitting port |
| SS-1210-P | Same, 3/4 in. size |
Valves follow their own families on the same grammar — the SS-4MG metering valve (1/4 in.), its 1/8 in. sibling SS-2MG and the bellows-sealed SS-4BMG read material + size + family letters the same way.
| Code | Tube OD | Common walls (seamless 316) | Typical duty |
|---|---|---|---|
| 2 | 1/8 in. | 0.028–0.035 in. | Gauge lines, analysers |
| 4 | 1/4 in. | 0.035–0.065 in. | The instrumentation standard |
| 6 | 3/8 in. | 0.035–0.065 in. | Impulse lines, gas supplies |
| 8 | 1/2 in. | 0.049–0.083 in. | Hydraulic-adjacent, sampling mains |
| 6M | 6 mm | 1.0–1.5 mm | The metric instrumentation standard |
| 10M | 10 mm | 1.0–1.5 mm | European panels |
| 12M | 12 mm | 1.0–2.0 mm | Supply headers |
The fitting's pressure rating assumes the tube's: ratings tables pair each OD/wall with an allowable working pressure (a 1/4 in. x 0.035 in. 316 line sits in the 5,000 psi class; thin-wall metric tube considerably lower), and gas service pushes wall thickness up the table for ferrule bite. The tube table in the maker's catalogue is the binding document — and thread identification for the other end of connectors lives in our BSP/NPT/metric thread chart.
What the mechanism refuses to forgive: dirt in the counterbore, tube not bottomed, torque-based make-up habits imported from compression plumbing, and hard tube that the ferrules cannot bite. On gas duty, leak-test with the proper fluid and accept zero bubbles — the instrument specification guide covers the loops these lines serve, and the calibrator guide the low-range leak-hunting that bad joints sabotage.
| System | Mechanism | Interchange position |
|---|---|---|
| Swagelok | Two-ferrule | The reference; complete-system certification |
| Parker A-LOK | Two-ferrule | Geometrically compatible class; operators' rules still forbid mixing within a joint |
| Parker CPI | Single-ferrule | Different mechanism; never mix components with two-ferrule systems |
| Ham-Let, Hy-Lok, Hoke Gyrolok | Two-ferrule / single by family | Same policy: whole joints only, per the site's written standard |
| DIN 2353 cutting ring | Bite-type on metric tube | A different world (hydraulics) — covered in the hydraulic fitting finder |
The defensible position for a plant or vessel: pick a primary system, write the no-mixed-joints rule, and hold spares of that system's ferrules and nuts per size. Where an installed base is mixed (every older vessel), survey by stamp — the part number grammar above reads any panel — and standardise forward rather than ripping out working joints.
A quotable line: system (Swagelok or accepted equivalent-class), material (316 default; 6Mo/Monel/Hastelloy for aggressive media with the 316-vs-304 logic behind it), tube size code, fitting style, end connection with thread standard explicit (NPT vs BSPT bites exactly here), quantity — plus the tube itself (OD, wall, material, annealed condition, mill certificate per EN 10204 3.1 where the piping class asks). Panels order by the kit: fittings, tube, gauge, deburrer, spare ferrule/nut sets per size.
How buying works at cballast. We quote instrumentation fittings, valves and tube by part number or by the decoded attribute set, with material certificates where specified, from Swagelok-class systems per the site's standard. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.
Sources referenced: Swagelok tube fitter's manual and catalogue data (part numbering, pull-up, gap gauge, retightening); tubing data tables for allowable working pressure; ASTM A269/A213 tube specifications; ASME B1.20.1 (NPT) and ISO 7/ISO 228 (BSP) threads; operators' instrumentation standards on system mixing.
Questions on a stamp, a size or a remake: write to sales@cballast.com. We answer whether or not you buy from us.