WIKA Pressure Gauge Selection & Range Chart — Type 232.50 / 233.50

Reference manual hosted for technician access. 1 pages.
Brand
WIKA
Equipment
316 SS Bourdon pressure gauge
Document type
Selection chart
Revision
WIKA PM 02.03 / PM 02.04
Issued
2026-07-05
Pages
1
Format
PDF (application/pdf)

WIKA Type 232.50 (dry) and Type 233.50 (glycerin-filled) 316 SS Bourdon pressure gauge selection chart: pressure range 0–1 bar through 0–1000 bar plus vacuum and compound ranges, digit stepping, EN 837-1 accuracy Class 1.0, preferred model and typical service. Includes rules for the working point (60–75 % of full scale), case sizes (63 / 100 / 160 mm), connection (G 1/4 B to G 1/2 B), when to fill, when to snub.

WIKA Pressure Gauge Selection & Range Chart — Type 232.50 / 233.50

A pressure gauge is selected against three things: (a) the pressure range and preferred working point, (b) the media wetted-part material and the service environment (vibration, pulsation, chemistry), and (c) the case size and connection to fit the installed thread pot and readable at the required distance. The WIKA Type 232.50 (dry) and Type 233.50 (glycerin-filled) are the industrial workhorses — 316L stainless wetted parts, EN 837-1 accuracy class 1.0, case sizes 63 / 100 / 160 mm, IP65.

RangeDigitClassPreferred typeTypical service
0–1 bar0.02 bar1.0PG23LT stainless preferredDiaphragm gauge — capsule on very low ranges.
0–1.6 bar0.02 bar1.0Type 232.50Standard Bourdon; lowest 232.50 range.
0–2.5 bar0.05 bar1.0Type 232.50General-service water, air, oil.
0–4 bar0.1 bar1.0Type 232.50Compressed-air distribution.
0–6 bar0.1 bar1.0Type 232.50Cooling-water headers.
0–10 bar0.2 bar1.0Type 232.50Hydraulic return.
0–16 bar0.5 bar1.0Type 232.50Steam headers, ballast systems.
0–25 bar0.5 bar1.0Type 232.50 / 233.50General industrial.
0–40 bar1 bar1.0Type 232.50 / 233.50Working-line hydraulics.
0–60 bar2 bar1.0Type 233.50 glycerinVibrating service — filled gauge.
0–100 bar2 bar1.0Type 233.50 glycerinHydraulic power packs.
0–160 bar5 bar1.0Type 233.50 glycerinRefinery hydraulic.
0–250 bar10 bar1.0Type 233.50 glycerinHydraulic tool / press.
0–400 bar10 bar1.0Type 233.50 glycerinHydraulic jack, punch.
0–600 bar20 bar1.0Type 233.50 glycerinHP test bench.
0–1000 bar20 bar1.0Type 233.50 glycerinHP test bench, wire-rope test.
−1…0 bar0.02 bar1.0Type 232.50 vacuumVacuum service.
−1…+1.5 bar0.05 bar1.0Type 232.50 compoundSuction lines.
−1…+5 bar0.2 bar1.0Type 232.50 compoundRefrigeration low-side.

Selecting the right range

Open / Download PDF

Document provided as a reference for technicians servicing installed equipment. Trademarks and copyright remain the property of WIKA. Consult WIKA or your service representative for the current revision before performing any maintenance or warranty work.