Mechanical Seals — Identification, EN 12756, Selection

Guide compiled by cBallast. 8-page PDF; the full content is on this page.
Compiled by
cBallast
Subject
Pump mechanical seals
Document type
Guide
Reference
2026 edition
Issued
2026-11-09
Pages
8
Format
Web page and PDF

How to identify, specify and replace a pump mechanical seal without the OEM drawing: the EN 12756 (DIN 24960) dimension system and its L1k working lengths, face material pairs from carbon/SiC to SiC/SiC and tungsten carbide, elastomer selection by medium and temperature, balanced against unbalanced and single against double arrangements, the API 682 flush-plan shorthand worth knowing ashore and afloat, failure-mode reading from the old seal, and the measurements that make a seal RFQ quotable in one pass.

The short version

1. Reading the old seal — identification that survives a seized pump

Measure / observeHowWhat it fixes
Shaft or sleeve diameterVernier on the shaft where the seal ran (d1)The headline size — EN 12756 runs the standard steps (10–100 mm)
Working length under compressionOld seal's set length, or housing depth vs seat positionShort vs long pattern; wrong length = no face load or coil-bind
Seat (stationary) type and O.D.G-type seat profiles: plain cup, O-ring mounted, clampedThe stationary half must fit the housing bore and its O-ring groove
Rotary constructionSingle spring, multi-spring, elastomer bellows, metal bellows, wave springBellows types forgive deposits on the shaft; multi-spring suits higher speeds
Face materialsCarbon is matte black and light; SiC dark grey, ceramic white, TC heavy metallicThe duty story the last engineer chose — upgrade knowingly, never downgrade blindly
ElastomersColour/feel is unreliable — go by medium and temperature insteadEPDM/FKM/NBR/FFKM selection per section 3
Drive and hardwareSet screws, drive pins, clamp ring; metal parts magnetic or not316-class (1.4401/1.4571) is the marine default; magnetic hardware in seawater duty is a finding

Send exactly that list — seven lines and two photos (face side, spring side) — and any competent supplier returns a quotable match. The pump nameplate (maker, type, impeller size) upgrades the answer from dimensional match to OEM-correct article, including the kit variants with sleeve and seat where the pump uses them.

2. Face material pairs

Pair (rotary/stationary)HabitatStrengthsLimits
Carbon / SiC (or carbon / ceramic in light duty)Clean water, seawater, oils, condensate — the general-service defaultForgiving, low friction, tolerates marginal lubricationCarbon wears in abrasives; ceramic cracks under thermal shock
SiC / SiCAbrasive, crystallising, high-temperature duty — e.g. SiC/SiC transfer-pump kits, tank-cleaning booster pumpsHardness, chemical breadth, heatNeeds a liquid film — dry running kills it fast; brittle to mechanical shock
Tungsten carbide / SiC or TC/TCSlurries, shock loads, sloppy operationToughness, dry-run abuse tolerance (relative)Weight, galvanic care in some media, price
Carbon / TCLegacy general duty at higher pressureProven at loadSuperseded by Car/SiC in most new work

3. Elastomers — where seals are really won and lost

ElastomerService windowRight forNever for
EPDM−40…+120 °C class (peroxide-cured higher)Hot fresh water, glycols, many chemicals, steam-adjacentMineral oils, fuels, greases — it swells and dies
FKM (Viton class)−15…+200 °C classOils, fuels, broad chemistry, airHot water/steam, amines, some esters — hydrolysis cracks it
NBR−30…+100 °C classCool oil and fuel duty, economy general serviceHeat, ozone/weathering, aggressive chemistry
FFKM (Kalrez/Chemraz class)to +230…320 °C by gradeAggressive solvents, acids, hot chemistry — see the FFKM compatibility chartBudgets that the duty does not justify

The failure chemistry is usually visible: swollen, gummy O-rings = wrong elastomer for the medium; hard, cracked rings = heat or the FKM-in-steam trap; nibbled rings = explosive decompression or installation damage. Replace the elastomer set to the medium, not to what happened to be in the box last time — and on drinking-water and food duty, specify the approval (WRAS/KTW/FDA class) on the line.

4. Arrangements and flush plans — the shorthand worth knowing

Single internal seal is the default; balanced construction (hydraulically relieved faces) takes higher pressures and runs cooler at the same duty — the step to specify above roughly 10–15 bar seal-chamber pressure or on sensitive media. Double seals (back-to-back with barrier fluid, or tandem with buffer) contain hazardous, crystallising or gassing media and buy dry-run security at the cost of a support system. The API 682 plan numbers name the plumbing around the seal, and the handful worth recognising on requisitions: Plan 11 (discharge recirculation through an orifice to the faces — the industrial default), Plan 13 (recirculation back to suction, vertical pumps), Plan 21 (cooled recirculation), Plan 23 (closed loop with cooler — hot water/boiler feed), Plan 32 (clean external flush into the chamber — slurries), Plan 52/53A-C (unpressurised/pressurised dual-seal support), Plan 62 (external quench — steam on hot hydrocarbon, water on crystallisers), Plan 65/66 (leakage detection). A seal RFQ that names the plan tells the supplier the duty's whole story in two characters.

5. Quotable lines and honest substitution

The complete RFQ line: pump (maker, type, serial if OEM-correct is wanted), shaft size and standard/length (EN 12756 short/long, or "cartridge — see photos"), faces / elastomers / metallurgy, medium, temperature, pressure, speed, and quantity with a spare set — because the pump that ate one seal will be opened again. Substitution rules we quote by: dimensional equivalents across John Crane, EagleBurgmann, Roten, Vulcan and AES classes are legitimate where every one of the five specification elements matches and the arrangement/plan is respected — stated as "dimensional equivalent to type X" on the line; OEM cartridges (Grundfos HQQE-class, 22 mm / 28 mm, HQQV 12 mm, or DESMI ROTAN kits) stay OEM-pattern unless the owner signs off a conversion. Related rotating-equipment references: the radial shaft seal guide for lip seals that neighbour the gland, and the ISO 4406 guide for the oil cleanliness that decides bearing and seal life together.

How buying works at cballast. We quote OEM and dimensional-equivalent seals side by side with the basis stated per line, kits with sleeves and seats where the pump uses them, and spare sets priced into the first quote. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.

Frequently asked questions

How do I identify a mechanical seal without a part number?
Measure the shaft diameter, establish the working length and whether the pattern is EN 12756 short or long, note the seat type, faces and elastomers, and photograph both sides. Those data quote a dimensional match; the pump nameplate upgrades it to the OEM-correct article.
What is EN 12756 / DIN 24960?
The European dimension standard for mechanical seals — shaft sizes, seat formats and working lengths. Its point is interchangeability: a compliant 25 mm short-pattern seal from any maker fits the same cavity. DIN 24960 is the historic name still printed on drawings; the content lives on as EN 12756.
Carbon/SiC or SiC/SiC faces — which do I need?
Carbon against silicon carbide for clean liquids — forgiving and the general default. SiC against SiC when the medium is abrasive, crystallising or hot. Hard/hard pairs need a decent liquid film; if the pump runs dry in normal operation, fix that or specify accordingly, because no face pair survives chronic dry running.
Which O-ring material for my pump seal?
By medium and temperature: EPDM for hot water and glycols (never oil), FKM for oils and fuels (never hot water/steam), NBR for cool oil economy duty, FFKM when aggressive chemistry rules the rest out. The elastomer set usually decides seal life before the faces do.
What is the difference between balanced and unbalanced seals?
Balanced seals geometrically relieve part of the hydraulic closing force, so the faces run cooler and survive higher pressures; unbalanced seals are simpler and fine at low pressure. Above roughly 10–15 bar in the seal chamber, or on heat-sensitive media, specify balanced.
What does API Plan 11 (or 52, 53) mean?
API 682 plan numbers describe the piping around the seal: Plan 11 recirculates discharge flow across the faces (the common default), Plan 23 runs a cooled closed loop, Plan 32 injects a clean external flush, Plans 52/53 support dual seals with unpressurised/pressurised barrier systems, Plan 62 quenches the atmospheric side. Naming the plan on an RFQ communicates the whole seal environment.
Can I replace an OEM cartridge seal with a generic one?
Sometimes — where dimensions, materials and arrangement genuinely match, a dimensional equivalent is legitimate and we state it as such on the quote. But cartridge geometries are often proprietary, and warranty or classed service may require OEM pattern. The honest answer is per-case, in writing, never a silent swap.
Who supplies mechanical seals and seal kits?
cballast.com quotes EN 12756 stock seals, OEM cartridges (Grundfos, DESMI ROTAN and peers) and dimensional equivalents with the basis stated per line — plus the elastomer sets and sleeves that belong with them. Write to sales@cballast.com with the seven identification lines above.

References and related guides

Standards and sources referenced: EN 12756 / DIN 24960 (dimensions), API 682 (seal systems and plans), seal manufacturers' engineering handbooks (John Crane, EagleBurgmann classes), elastomer compatibility data per compound makers.

Questions on a seal identification or a substitution judgement: write to sales@cballast.com. We answer whether or not you buy from us.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.