Danfoss VLT Drives — FC Family Map, MCB Option Cards, LCP Panels and Coated Boards

Selection guide compiled by cBallast. 3-page PDF; the full content is on this page.
Brand
Danfoss
Subject
Variable frequency drives
Document type
Selection guide
Reference
2026 edition
Issued
2026-10-18
Pages
3
Format
Web page and PDF

Which VLT family fits which duty (FC-51 through FC-302), what the reference's kW, voltage band and IP class mean on a replacement, the MCB option-card system (general-purpose I/O, relay cards), LCP control panels as separate items, and why conformal-coated boards matter — grounded in the stocked range.

The FC number places the drive

FamilyBuilt forStocked examples
FC-51 / FC-101 (Micro/HVAC Basic)Simple speed control, compact panelsquoted per rating
FC-102 / FC-202 (HVAC / AQUA)Fans, pumps, water and wastewater — pump-specific software (sleep, pipe-fill, dry-run detection)FC-202 11 kW IP55, 30 kW IP55, 30 kW 200–240 V
FC-302 (AutomationDrive)General machinery, high dynamic performance, safety (STO)11 kW IP20, 22 kW IP55, 90 kW IP54

A like-for-like swap needs four matches off the old unit's plate: family, kW at the duty's overload class, voltage band (the stocked rows show why — the same 30 kW AQUA exists in 380–480 V and 200–240 V builds), and enclosure (IP20 for cabinets, IP54/55 wall-mounted). The 131…/134… code on the plate pins the exact configuration including options; quote it whole. Cross-brand equivalents sit in the VFD cross-reference.

Options and spares are their own part numbers

Around 240 VLT line items are stocked — drives, option cards, panels — under Danfoss. Motor-side selection (frame, efficiency class, duty) pairs with the IEC frame chart and IE-class guide; a nameplate photo of drive and motor together gets both ends quoted in one 24-hour pass.

Frequently asked questions

Can an FC-302 replace an FC-202?
Downward, usually yes — the AutomationDrive is the superset — but the AQUA software features (pipe-fill, flow compensation) and parameter layout differ, so a straight parameter copy is not possible and commissioning is redone. Like-for-like family swaps stay simplest.
What does ctd mean in a Danfoss option card reference?
Conformal-coated circuit board — the humidity/corrosion-protected build. Coated and uncoated versions carry different part numbers; environments that justified coating once require it on every card that goes in.
Is the kW rating on a VFD the motor's kW?
It is the drive's rating at a stated overload profile — a pump duty (low overload) and a machinery duty (high overload) can land one size apart for the same motor. Match the old drive's rating and duty class, or size from the motor's full-load current.
Can I move the LCP panel from the old drive to the new one?
Yes within the platform — LCPs are deliberately detachable spares, and a graphic LCP additionally carries parameter backups across. Confirm panel compatibility when crossing families.
Why does my replacement drive trip where the old one ran?
Newer firmware defaults differ: motor data not auto-tuned, switching frequency, or ramp times. Run the motor adaptation routine and transfer the old parameter set before suspecting hardware.
Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.