Sensor cable for Trojan ultraviolet intensity sensors of the 20 mA = 100 W scaling. It carries the sensor’s 4-20 mA current loop back to the controller. A current loop is used precisely so that the reading does not drift with cable length or contact resistance, but that only holds while the cable and its glands are intact: water ingress at a sensor connector shows up as an intensity reading that wanders or reads low, which is easily mistaken for a failing lamp or a fouled sleeve. Quote the sensor scaling when ordering. Contact us if you are unsure whether this part fits your UV system.
| Product type | Sensor cable |
| Signal | 4-20 mA current loop |
| For sensor scaling | 20 mA = 100 W |
| Fits | Trojan UV intensity sensors of the 20 mA = 100 W scaling |
| Condition | New replacement part |
| Reference number | 1560-1107 |
| HS code | 8543.70 |
| MOQ | 1 |
Genuine Trojan replacement part for Trojan UV disinfection systems.