cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Telemecanique XUK8TAE2MM12 Photoelectric Distance Sensor, 0–1.5 m, 4–20 mA, M12 Connector

Telemecanique · Sensors & Instrumentation · Pressure Transmitters
Part Number
XUK8TAE2MM12  ·  HS 8536.90
Telemecanique XUK8TAE2MM12 Photoelectric Distance Sensor, 0–1.5 m, 4–20 mA, M12 Connector

Telemecanique XUK8TAE2MM12 photoelectric distance sensor (time of flight), adjustment range 0–1500 mm, 1 switching output plus 4–20 mA analogue output, M12 connector.

Technical Specifications

Manufacturer part number (MPN)XUK8TAE2MM12
EAN / GTIN3666916037478
HS code8536.90
Sales unitpcs
Package quantity28 pcs
Adjustment range0–1500 mm
TriangulationBackground fade-out
Pre failure noticeNo
With time functionNo
Rated switching distance5000 mm
Max. switching distance1500 mm
Max. output current60 mA
With reflectorNo
Analogue output 0 V ... 10 VNo
Analogue output 0 mA ... 20 mANo
Analogue output 4 mA ... 20 mANo
Analogue output -10 V ... +10 VNo
With other analogue outputNo
With communication interface analogueNo
With communication interface AS-InterfaceNo
With communication interface CANOpenNo
With communication interface DeviceNetNo
With communication interface EthernetNo
With communication interface INTERBUSNo
With communication interface PROFIBUSNo
With communication interface RS-232No
With communication interface RS-422No
With communication interface RS-485No
With communication interface SSDNo
With communication interface SSINo
Type of electric connectionConnector M12
Type of switching outputPNP/NPN
Type of switch functionProgrammable/configurable
Operation agent-safety classSafety class 0
Construction type housingCuboid
Width sensor18 mm
Height of sensor50 mm
Length of sensor50 mm
Sensing modeLight switching
Material of optical surfacePlastic
Housing materialPlastic
Max. output current at protected output100 mA
Min. reflector distance0 mm
Ambient temperature-40–80 °C
Response time1.2 ms
Switching frequency250 Hz
Type of safety according to IEC 61496-11
Rated control supply voltage AC 50 Hz24–240 V
Rated control supply voltage AC 60 Hz24–240 V
Rated control supply voltage DC24–240 V
With monitoring function downstream switching devicesNo
Laser protection classClass 1
Type of lightLaser diode, infrared light
With restart blockageNo
Suitable for safety functionsNo
Degree of protection (IP)IP67K
Operating distance0–1500 mm
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents