| Product type | Push buttons |
| Product group | Push buttons and signal units |
| Series | Harmony XB6 |
| Color | Red |
| Contact type | 1NO -1NC |
| Diameter | 16 mm |
| Sales unit | Carton |
| Carbon footprint (EPD) | 0.0856 kg CO2e per pcs |
| Country of origin | France |
| Customs tariff code (EU CN) | 85365080 |
| HS code | 8536.50 |
| Manufacturer part number | XB6AA45B |
| Range of product | Harmony XB6 |
| Product or component type | Complete push-button |
| Device short name | XB6 |
| Bezel material | Plastic |
| Mounting diameter | 16 mm |
| Sale per indivisible quantity | 1 |
| Shape of signaling unit head | Round |
| Type of operator | spring return |
| Operator profile | Red flush, unmarked |
| Contacts type and composition | 1 NO + 1 NC |
| Contact operation | Slow-break |
| Connections - terminals | Faston connectors, connection size: 2.8 x 0.5 mm |
| CAD overall width | 18 mm |
| CAD overall height | 18 mm |
| CAD overall depth | 57 mm |
| Terminals description ISO n°1 | (13-14)NO; (21-22)NC |
| Product weight | 0.022 kg |
| Operating position | Any position |
| Positive opening | With conforming to IEC 60947-5-1 appendix K |
| Operating travel | 1 mm (NO changing electrical state); 2 mm (NC changing electrical state); 3.5 mm (total travel) |
| Operating force | 3.5 N NO changing electrical state; 4.5 N NC changing electrical state |
| Mechanical durability | 2000000 cycles |
| Contacts material | Silver alloy (Ag/Ni) |
| Short-circuit protection | 6 A cartridge fuse type gG |
| [Ui] rated insulation voltage | 250 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 60947-1 |
| [Ie] rated operational current | 3 A at 120 V, AC-15, B300 conforming to IEC 60947-5-1; 1.5 A at 240 V, AC-15, B300 conforming to IEC 60947-5-1; 0.1 A at 250 V, DC-13, R300 conforming to IEC 60947-5-1; 0.22 A at 125 V, DC-13, R300 conforming to IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Electrical reliability | Λ = 10exp(-8) at 5 V and 1 mA with confidence level of 90 % conforming to IEC 60947-5-4 |
| Protective treatment | TC |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -25…70 °C |
| Electrical shock protection class | Class II conforming to IEC 61140 |
| IP degree of protection | IP65 conforming to IEC 60529 |
| NEMA degree of protection | NEMA 13 conforming to UL 50; NEMA 4 conforming to UL 50; NEMA 4X conforming to UL 50; NEMA 13 conforming to CSA C22.2 No 94; NEMA 4 conforming to CSA C22.2 No 94; NEMA 4X conforming to CSA C22.2 No 94 |
| Standards | IEC 60947-5-5; IEC 60947-5-1; CSA C22.2 No 14; JIS C 852; JIS C 4520; IEC 60947-1; UL 508 |
| Product certifications | CSA; GOST; CCC; UL |
| Vibration resistance | +/- 3 mm (f= 2…500 Hz) conforming to IEC 60068-2-6; 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn (duration = 18 ms) for half its wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half its wave acceleration conforming to IEC 60068-2-27 |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 75 |
| Warranty (in months) | 18 |
| EAN | 3389110764345 |