Schneider LP1D Contactor. Contactors and thermal relays (Electrical Engineering / Components for panels and boxes). Principal data: series TeSys D, current 65 A, number of poles 4P. Supplied under manufacturer part number LP1D65004BD, EAN 3389110234237, HS code 8536.49, country of origin Czechia.
| Product type | Contactors and thermal relays Product group: Components for panels and boxes Series: TeSys D Current: 65 A Number of poles: 4P Carbon footprint (EPD): 12.8905 kg CO2e per pcs Country of origin: Czechia Customs tariff code (EU CN): 85364900 HS code: 8536.49 Manufacturer part number: LP1D65004BD Range of product: TeSys Deca Product or component type: Contactor Device short name: LP1D Contactor application: Resistive load Utilisation category: AC-1; AC-3; AC-3e; AC-4 Poles description: 4P [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz [Ie] rated operational current: 80 A (at <60 °C) AC AC-1 for power circuit [Uc] control circuit voltage: 24 V DC Compatibility code: LP1D Pole contact composition: 4 NO Protective cover: With [Ith] conventional free air thermal current: 10 A (at 60 °C) for control circuit; 80 A (at 60 °C) for power circuit Irms rated making capacity: 1000 A at 440 V for power circuit conforming to IEC 60947; 250 A AC for control circuit conforming to IEC 60947-5-1 Rated breaking capacity: 1000 A at 440 V for power circuit conforming to IEC 60947 Associated fuse rating: 10 A gG for control circuit conforming to IEC 60947-5-1; 125 A gG at <= 690 V coordination type 2 for power circuit; 160 A gG at <= 690 V coordination type 1 for power circuit Average impedance: 1 mOhm - Ith 80 A 50 Hz for power circuit Power dissipation per pole: 9.6 W AC-1 [Ui] rated insulation voltage: Control circuit: 600 V CSA certified; Control circuit: 600 V UL certified; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Control circuit: 690 V conforming to IEC 60947-1; Power circuit: 690 V conforming to IEC 60947-1 Overvoltage category: III [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 Mechanical durability: 10 Mcycles Control circuit type: DC standard Coil technology: Built-in bidirectional peak limiting diode suppressor Control circuit voltage limits: 0.1...0.3 Uc (60 °C):drop-out DC; 0.75...1.25 Uc (60 °C):operational DC Inrush power in W: 19 W (at 20 °C) Hold-in power consumption in W: 7.4 W at 20 °C Rated operational power in W: 14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit; 48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit; 96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit Operating time: 20 ms opening; 50 ms closing Time constant: 34 ms Maximum operating rate: 3600 cyc/h at 60 °C Connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 1…35 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 1…25 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 1…35 mm² - cable stiffness: solid without cable end Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2; Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 to Ø 8 mm Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 minimum switching voltage: 17 V for control circuit minimum switching current: 5 mA for control circuit Insulation resistance: > 10 MOhm for control circuit Non-overlap time: 1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts Mounting support: Plate; Rail Standards: EN 60947-1; IEC 60947-4-1; EN 60947-4-1; IEC 60947-1; BS 5424; NF C 63-110; JEM 1038; VDE 0660 Product certifications: GL; PTB; CSA; DNV; SNCF; Sichere trennung; UL; GOST; RINA; UKCA IP degree of protection: IP2X conforming to IEC 60529; IP2X conforming to VDE 0106 Protective treatment: TH (pollution degree 3) conforming to IEC 60068 Permissible ambient air temperature around the device: -5…60 °C; -40…70 °C at Uc Operating altitude: 3000 m without derating Fire resistance: 850 °C conforming to IEC 60695-2-1 Flame retardance: V1 conforming to UL 94 Mechanical robustness: Shocks contactor open (8 Gn for 11 ms) ; Shocks contactor closed (10 Gn for 11 ms) ; Vibrations contactor opened (2 Gn, 5...300 Hz) ; Vibrations contactor closed (3 Gn, 5...300 Hz) Height: 127 mm Width: 85 mm Depth: 182 mm Product weight: 2.21 kg Warranty (in months): 18 EAN: 3389110234237 |
| MOQ | 1 |