| Manufacturer part number (MPN) | A9MEM3350 |
| EAN / GTIN | 3606480696411 |
| Sales unit | pcs |
| Package quantity | 18 pcs |
| Rated current | 125 A |
| Range | Acti9 |
| range of product | Acti9 iEM3000 |
| Product or component type | Energy meter |
| Device short name | iEM3350 |
| Market segment | Buildings small building cost management: billing: main incomer; Buildings small building cost management: billing: sub feeder; Buildings small building cost management: billing: panelboard; Buildings medium building cost management: billing: main incomer; Buildings medium building cost management: billing: sub feeder; Buildings medium building cost management: billing: panelboard; Buildings large building cost management: billing: main incomer; Buildings large building cost management: billing: sub feeder; Buildings large building cost management: billing: panelboard; Buildings multi-site cost management: billing: main incomer; Buildings multi-site cost management: billing: sub feeder; Buildings multi-site cost management: billing: panelboard; Data center cost management: billing; Healthcare cost management: billing; Industry cost management: billing; Buildings small building cost management: cost allocation: main incomer; Buildings small building cost management: cost allocation: sub feeder; Buildings small building cost management: cost allocation: panelboard; Buildings medium building cost management: cost allocation: main incomer; Buildings medium building cost management: cost allocation: sub feeder; Buildings medium building cost management: cost allocation: panelboard; Buildings large building cost management: cost allocation: main incomer; Buildings large building cost management: cost allocation: sub feeder; Buildings large building cost management: cost allocation: panelboard; Buildings multi-site cost management: cost allocation: main incomer; Buildings multi-site cost management: cost allocation: sub feeder; Buildings multi-site cost management: cost allocation: panelboard; Data center cost management: cost allocation; Healthcare cost management: cost allocation; Industry cost management: cost allocation |
| Poles description | 3P + N; 3P; 1P + N |
| Type of measurement | Active energy; Current; Voltage; Active power |
| Device application | Partial meter; Sub billing |
| Accuracy class | Class 1 active energy conforming to IEC 62053-21; Class 1 active energy conforming to IEC 61557-12 |
| input type | Direct connection |
| [In] rated current | 125 A |
| Rated voltage | 100…277 V; 173…480 V |
| Network frequency | 50 Hz; 60 Hz |
| Technology type | Electronic |
| Display type | LCD display |
| Sampling rate | 32 samples/cycle |
| Measurement current | 0…125 A |
| Maximum value measured | 99999999.9 kWh |
| Communication port protocol | Modbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V |
| Communication port support | Screw terminal block: RS485 |
| Local signalling | Green indicator light: power ON; Yellow flashing LED: accuracy checking; Yellow indicator light: communications are active on the Modbus port (Modbus) |
| Number of inputs | 0 |
| Number of outputs | 0 |
| mounting mode | Clip-on |
| Mounting support | DIN rail |
| Connections - terminals | Screw terminals 50 mm² cable(s) |
| Overvoltage category | III |
| Standards | BS EN 61557-12:2021; IEC 61557-12:2021; EN 61557-12:2021; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11:2020; IEC 62052-11:2020; EN 62052-11:2020; BS EN 62053-21; IEC 62053-21; EN 62053-21; BS EN 62052-31:2015; IEC 62052-31:2015; EN 62052-31:2015; BS EN 61010-1:2010; EN 61010-1:2010; IEC 61010-1:2010; UL 61010-1:2010; BS EN 61010-2-30; IEC 61010-2-30; EN 61010-2-30; UL 61010-2-30; ANSI C12.16 |
| Product certifications | CE conforming to IEC 61010-1 (safety); CE conforming to EN 61557-12 (power monitor); CE conforming to EN/IEC 61326-1 (EMC); UKCA conforming to BS EN 61010-1 (safety); UKCA conforming to BS EN 61557-12 (power monitor); UKCA conforming to BS EN 61326-1 (EMC); CULus conforming to UL 61010-1 (safety); CULus conforming to EN 61010-1 (safety); EAC (sub-meter); KZ conforming to NMI M 6-1; KZ; NMI conforming to NMI M 6-1 |
| Compatibility code | IEM3350 |
| IP degree of protection | IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529 |
| Pollution degree | 2 |
| Relative humidity | 5…95 % at 50 °C |
| Ambient air temperature for operation | -25…70 °C - IEC |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | < 3000 m |
| Colour | White |
| 9 mm pitches | 14 |
| Width | 126 mm |
| Height | 103.2 mm |
| Depth | 69.3 mm |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 18 |
| Warranty (in months) | 18 |
| Mounting method | DRA (DIN-rail adaptor) |
| Model | Direct measurement |
| Suitable for | Purchase |
| Type of indication | Digital |
| Frequency | 50–60 Hz |
| Max. current (Imax) | 125 A |
| Width in number of modular spacings | 7 |
| Number of positions total (counter) | 9 |
| Type of meter | Electronic |
| Degree of protection (IP) | IP20 |
| Type of interface | Modbus |
| Energy type | Effective power |
| Tariff type | One-tariff |
| Tariff control | Internal |
| Escapement mechanism | No |
| Calibrated | No |
| Approval | Domestic |
| Pulse output | Optical |
| Pulse type | S0 |
| Pulse rate | 0–500 Imp/kWh (kvarh) |
| Pole type | Three conductor/four conductor |
| Measurement type load profile | No |
| EEC40 signature | No |
| With lock code | No |
| Nominal voltage (Un) N-L | 100–277 V |
| Nominal voltage (Un) L-L | 173–480 V |
| Nominal current (In) | 125 A |
| Country of origin | China |