Schneider Electric PM5563 Meter, 2 ethernet, up to 63TH H, 1,1M 4DI/2DO 52 alarms, DIN mounted METSEPM5563

Schneider Electric · Electrical Components · Energy Meters · France · se.com
Part Number
METSEPM5563  ·  HS 9028.30
Schneider Electric PM5563 Meter, 2 ethernet, up to 63TH H, 1,1M 4DI/2DO 52 alarms, DIN mounted METSEPM5563

Schneider Electric METSEPM5563 Power analyser PM5563. 690V, without frontdisplay. Modbus+Ethernet.

Technical Specifications

Manufacturer part number (MPN)METSEPM5563
EAN / GTIN3606480614088
Sales unitpcs
Package quantity12 pcs
RangePowerLogic
Product namePowerLogic PM5000
Product or component typePower meter
Device short namePM5563
Power quality analysisup to the 63rd harmonic
Metering typeMeasured neutral current; Calculated ground current
Device applicationPower monitoring; WAGES metering; Gateway; Multi-tariff
Type of measurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] rated supply voltage100...300 V DC; 90...528 V AC 45...65 Hz
Network frequency60 Hz; 50 Hz
[In] rated current5 A; 1 A
type of network1P + N; 3P; 3P + N
Maximum power consumption in VA16 VA at 480 V
Ride-through time35 ms 120 V AC typical; 129 ms 230 V AC typical; 50 ms 125 V DC typical
Display typeWithout display
Sampling rate128 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance <= 0.3 mOhm)
Measurement voltage20…400 V AC 45...65 Hz between phase and neutral; 20…828 V AC 45...65 Hz between phases
Frequency measurement range45…65 Hz
Number of inputs4 digital
Measurement accuracyApparent power +/- 0.5 %; Frequency +/- 0.05 %; Active energy +/- 0.2 %; Reactive energy +/- 1 %; Active power +/- 0.2 %; Voltage +/- 0.1 %; Power factor +/- 0.005; Current +/- 0.15 %; Reactive power +/- 1 %
Accuracy classClass 0.2S active energy conforming to IEC 62053-22
Number of outputs2 digital
Information displayedTariff (8)
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V; JBUS; Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V; Ethernet Modbus TCP/IP daisy chain; BACnet IP; DNP3 over ethernet
Communication port supportRS485; ETHERNET
Communication gatewayEthernet/serial
Data recordingMaintenance logs; Event logs; Alarm logs; Time stamping; Data logs; Min/max of instantaneous values
Memory capacity1.1 MB
Web servicesAlarm notification by e-mail; Diagnostic via predefined web pages; Web server; Real time viewing of data
Ethernet serviceSNMP-Traps; SNTP client
Connections - terminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; RS485 link: screw terminal block4; Digital input: screw terminal block8; Digital output: screw terminal block4; Ethernet network: RJ45 connector2
mounting modeClip-on
Mounting supportDIN rail
StandardsEN 50470-1; IEC 60529; IEC 62053-24; UL 61010-1; IEC 62053-22:2020; IEC 61557-12:2015; EN 50470-3; ANSI C12.20; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1; BTL
Width96 mm
Depth72 mm
Height96 mm
Product weight450 g
Electromagnetic compatibilityLimits for harmonic current emissions class A conforming to IEC 61000-3-2; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency level 4 conforming to IEC 61000-4-8; Conducted and radiated emissions class B conforming to EN 55022; Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Surge immunity test level 4 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protectionIP54 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude<= 3000 m
Number of Units in Package 11
Number of Units in Package 212
Country of originIN
Warranty (in months)18
Measured value memoryYes
Power factorYes
Suitable for RJ plugNo
Step angle (cos phi)Yes
Harmonics measurementYes
Pulse outputOptical
CalibratedNo
Max. current (Imax)20 A
Measurement type load profileYes
With communication interface KNXNo
With communication interface M-BusNo
With communication interface RS-485Yes
ModelMeasurement transformer
Mounting methodDIN rail
Nominal current (In)5 A
Pole typeThree conductor/four conductor
Apparent powerYes
Connectable conductor cross section solid-core0.82–3.31 mm²
Ampere meterYes
Reactive power meterYes
With rotational speed meterNo
Frequency meterYes
Pulse counterNo
VoltmeterYes
Effective power measurement deviceYes
Accuracy class active energy according to IEC 62053-220.2S
Sampling frequency12800 Hz
Number of voltage measurement inputs4
Number of current measurement inputs8
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz100–480 V
Supply voltage AC 60 Hz100–480 V
Supply voltage DC125–250 V
Measuring range for frequency45–65 Hz
DisplayOptional
Remote displayNo
Display resolution (horizontal)128 px
Number of digital inputs2
Number of digital outputs4
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for OPC UA PubSubNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFINET IONo
Supporting protocol for other bus systemsYes
With audit logging (audit log)Yes
With firmware signatureNo
With logging of security events (security event log)Yes
With Role Based Access Control (RBAC)No
Web server with HTTPS transfer protocolYes

Properties

MOQ1

Cross-References