cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric PM5111 Meter, modbus, up to 15TH H, 1DO 33 alarms, MID METSEPM5111

Schneider Electric · Electrical Components · Energy Meters · France · se.com
Part Number
METSEPM5111  ·  HS 9028.30
Schneider Electric PM5111 Meter, modbus, up to 15TH H, 1DO 33 alarms, MID METSEPM5111

Schneider Electric METSEPM5111 Power analyser PM5110. 690V, Modbus and 1 digital output. MID certified.

Technical Specifications

Manufacturer part number (MPN)METSEPM5111
EAN / GTIN3606480624513
Sales unitpcs
Package quantity12 pcs
RangePowerLogic
Product namePowerLogic PM5000
Product or component typePower meter
Device short namePM5111
Power quality analysisup to the 15th harmonic
Device applicationPower monitoring
Type of measurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] rated supply voltage90...450 V AC 45...65 Hz; 100...300 V DC
Network frequency50 Hz; 60 Hz
[In] rated current5 A; 1 A
type of network3P; 1P + N; 3P + N
Maximum power consumption in VA11 VA at 415 V
Ride-through time80 ms 120 V AC typical; 100 ms 230 V AC typical; 100 ms 415 V AC typical
Display typeMonochrome graphic LCD
Display resolution128 x 128 pixels
Sampling rate64 samples/cycle
Measurement current50…8500 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance <= 0.3 mOhm)
Measurement voltage35…760 V AC 45...65 Hz between phases; 20…440 V AC 45...65 Hz between phase and neutral
Frequency measurement range45…65 Hz
Number of inputs0
Measurement accuracyActive energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.5; Current +/- 0.5 %; Voltage +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy classClass 0.5S active energy conforming to IEC 62053-22
Number of outputs1 digital
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V; JBUS
Communication port supportRS485
Data recordingTime stamping; Min/max of instantaneous values
Connections - terminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; RS485 link: screw terminal block4
mounting modeFlush-mounted
Mounting supportFramework
StandardsIEC 61557-12:2015; EN 50470-1; UL 61010-1; IEC 62053-24; IEC 60529; EN 50470-3; IEC 62053-22:2020; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1; MID conforming to EN 50470-1; MID conforming to EN 50470-3
Width96 mm
Depth72 mm
Height96 mm
Product weight380 g
Electromagnetic compatibilitySurge immunity test class A conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test level 4 conforming to IEC 61000-4-11; Limits for harmonic current emissions class A conforming to IEC 61000-3-2; Electrostatic discharge level 4 conforming to IEC 61000-4-2; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency level 4 conforming to IEC 61000-4-8; Conducted and radiated emissions class B conforming to EN 55022; Immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Surge immunity test conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Conducted RF disturbances conforming to IEC 61000-4-6; Immunity to impulse waves conforming to IEC 61000-4-12
IP degree of protectionIP54 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display
Ambient air temperature for storage-40…85 °C
Operating altitude2000 m CAT III; 3000 m CAT II
Number of Units in Package 11
Number of Units in Package 212
Number of Units in Package 396
Country of originIN
Warranty (in months)18
EAN3606480613999
Measured value memoryNo
Power factorYes
Suitable for RJ plugNo
Step angle (cos phi)Yes
Harmonics measurementYes
Pulse outputOptical
CalibratedNo
Max. current (Imax)20 A
Measurement type load profileYes
With communication interface KNXNo
With communication interface M-BusNo
With communication interface RS-485Yes
ModelMeasurement transformer
Mounting methodFront mounting
Nominal current (In)5 A
Pole typeThree conductor/four conductor
Apparent powerYes
Connectable conductor cross section solid-core0.82–3.31 mm²
Ampere meterYes
Reactive power meterYes
With rotational speed meterNo
Frequency meterYes
Pulse counterNo
VoltmeterYes
Effective power measurement deviceYes
Accuracy class active energy according to IEC 62053-220.5S
Sampling frequency6400 Hz
Number of voltage measurement inputs4
Number of current measurement inputs6
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz100–415 V
Supply voltage AC 60 Hz100–415 V
Supply voltage DC125–250 V
Measuring range for frequency47–63 Hz
DisplayLCD
Remote displayNo
Number of digital outputs1
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for OPC UA PubSubNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFINET IONo
Supporting protocol for other bus systemsYes
With audit logging (audit log)No
With firmware signatureNo
With logging of security events (security event log)Yes
With Role Based Access Control (RBAC)No
Web server with HTTPS transfer protocolNo

Properties

MOQ1

Cross-References

Attached Documents