| Manufacturer part number (MPN) | A9MEM1580 |
| EAN / GTIN | 3606481595270 |
| Sales unit | pcs |
| Package quantity | 24 pcs |
| Rated current | 160 A |
| Number of poles | 3P |
| Range of product | PowerLogic |
| Product name | PowerTag F160 |
| Product or component type | Energy sensor |
| Poles | 3P; 3P + N |
| Maximum current [Imax] | 160 A |
| [Ib] Basic current | 25 A |
| Starting current | 100 mA |
| Saturation current | 320 A |
| Product specific application | Energy management; Overload alarm; Power factor; Load monitoring; Circuit monitoring |
| Concentrator compatibility | EcoStruxure Panel Server Entry; EcoStruxure Panel Server Universal; EcoStruxure Panel Server Advanced; Harmony Hub; Acti9 PowerTag Link; Acti9 PowerTag Link HD |
| Range compatibility | Acti9 Acti9 C120; Acti9 Acti9 NG125; ComPacT ComPact NSXm; TeSys TeSys GV4; ComPacT ComPacT INS; Acti9 Acti9 iSW; Acti9 Acti9 iSW-NA; Acti9 Acti9 iID; PowerPact PowerPact B |
| Type of measurement | Active and reactive energy; Apparent energy; Active and reactive power; Apparent power; Current; Voltage; Power factor; Internal temperature; Frequency |
| Accuracy class | Class 1 active energy conforming to IEC 61557-12; Class 2 reactive energy conforming to IEC 61557-12; Class 2 apparent energy conforming to IEC 61557-12; Class 1 active power conforming to IEC 61557-12; Class 2 reactive power conforming to IEC 61557-12; Class 2 apparent power conforming to IEC 61557-12; Class 1 current conforming to IEC 61557-12; Class 0.5 voltage conforming to IEC 61557-12; Class 1 power factor conforming to IEC 61557-12; Class 0.5 frequency conforming to IEC 61557-12 |
| Metering type | Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at total per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at partial per phase; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase total; Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase partial; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at total per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at partial per phase; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase total; Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase partial; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at total per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at partial per phase; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase total; Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase partial; Active power P, P1, P2, P3; Reactive power Q, Q1, Q2, Q3; Apparent power S, S1, S2, S3; Current I1, I2, I3; Calculated neutral current; Voltage U12, U23, U31; Voltage V1N, V2N, V3N; Frequency 45...65 Hz; Power factor at per phase; Power factor at total |
| Mounting location | Top or bottom |
| Mounting support | Cables |
| Connection pitch | 27 mm |
| Product destination | Switchboard |
| Event management | Voltage loss with measured current at voltage loss |
| Transmission support medium | Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4 |
| Emission power | 10 mW |
| Form factor | Flex |
| Mounting mode | Free mounting |
| Electrical connection (voltage sensing & power supply) | Removable spring terminal block |
| Cable cross section | 1 rigid cable 0.2…1.5 mm² without cable end; 1 stranded cable 0.2…2.5 mm² without cable end; 1 stranded cable 0.25…1.5 mm² with cable end |
| Wire stripping length | 11 mm |
| max power cable diameter | 17 mm |
| supply voltage | 100...277 V AC, +/- 20 %, phase to neutral; 173...480 V AC, +/- 20 %, phase to phase |
| Network frequency | 50 Hz; 60 Hz |
| Maximum power consumption | 3 VA |
| Standards | IEC 61557-12; IEC 61010-1; ETSI EN 301 489-1; IEC 61010-2-030; IEC 61326-1; ETSI EN 300 328 |
| Product certifications | UL listed; IEC; DNV Marine |
| Height | 39 mm |
| Width | 91 mm |
| Depth | 62 mm |
| Product weight | 80 g |
| Colour | White (RAL 9003) |
| Quality labels | CE |
| Directives | 2014/53/EU - radio equipment directive |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Overvoltage category | IV conforming to IEC 61010-1 |
| Measurement category | Category IV conforming to IEC 61010-2-030 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| IK degree of protection | IK05 |
| Pollution degree | 3 |
| Relative humidity | 0…95 % at 55 °C conforming to IEC 60721-3-3 |
| Vibration resistance | 3M4 conforming to IEC 60721-3-3 |
| Electromagnetic compatibility | Industrial electromagnetic environment conforming to IEC 61326-1; Radiated EMC conforming to ETSI EN 301 489-17; Electromagnetic emission conforming to IEC 62311 |
| environmental characteristics | Indoor use |
| Country of origin | LV |
| Warranty (in months) | 18 |
| Mounting method | Plug-in technique |
| Model | Direct measurement |
| Suitable for | Purchase |
| Type of indication | None |
| Power consumption | 3 W |
| Max. current (Imax) | 160 A |
| Width in number of modular spacings | 5 |
| Type of meter | Electronic |
| Degree of protection (IP) | IP20 |
| Energy type | Effective power and reactive power |
| Tariff type | One-tariff |
| Escapement mechanism | No |
| Calibrated | Yes |
| Approval | Domestic |
| Pulse output | None |
| Pole type | Four conductor |
| Measurement type load profile | No |
| EEC40 signature | No |
| With lock code | No |
| Nominal current (In) | 160 A |