Schneider Electric PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering METSEPM8240

Schneider Electric · Sensors & Instrumentation · Energy Meters · France · se.com
Part Number
METSEPM8240  ·  HS 9028.30
Schneider Electric PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering METSEPM8240

Schneider Electric METSEPM8240 PM8240 advanced power analyser for flush (panel) mounting.

Technical Specifications

Manufacturer part number (MPN)METSEPM8240
EAN / GTIN3606480701931
Sales unitpcs
Package quantity8 pcs
RangePowerLogic
Product namePowerLogic PM8000
Product or component typePower meter
Device short namePM8240
Market segmentBuildings large building cost management: billing: sub feeder; Buildings small building network management: main incomer; Buildings medium building network management: main incomer; Buildings large building network management: main incomer; Buildings large building network management: sub feeder; Buildings multi-site network management: main incomer; Buildings multi-site network management: sub feeder; Data center network management: main incomer; Data center network management: sub feeder; Healthcare network management: main incomer; Healthcare network management: sub feeder; Industry network management: main incomer; Industry network management: sub feeder; Utility: sub feeder
model typeStandard
Power quality analysisconforming to EN 50160: 2010 compliance report; conforming to IEEE 519: 2014 compliance report; conforming to IEC 61000-4-30: class S power quality measurement; up to the 63rd harmonic; harmonic distortion; waveform capture; voltage sag and swell detection; programmablity (logic and math functions); conforming to IEC 62586 power quality monitoring; disturbance direction detection; rapid voltage change
Device applicationPower monitoring; WAGES metering
Type of measurementCurrent; Voltage; Frequency; Active and reactive power total; Apparent power total; Power factor total; Active and reactive power per phase, rms; Apparent power per phase, rms; Power factor per phase, rms
supply voltage90...415 V AC 45...65 Hz +/- 10 %; 110...415 V DC +/- 10 %
Network frequency50 Hz; 60 Hz
[In] rated current1 A; 5 A; 10 A
Poles description3P + N; 3P; 1P + N
Power consumption in VA16 VA at 230 V AC
Display typeColour TFT LCD
Display resolution320 x 240 pixels QVGA
Sampling rate256 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm); Current (impedance 0.3 mOhm)
Measurement voltage57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases
Frequency measurement range42…69 Hz
Number of inputs3 digital 30 V AC; 3 digital 60 V DC
Measurement accuracyCurrent +/- 0.1 %; Voltage +/- 0.1 %; Active energy +/- 0.2 %
Accuracy classClass 0.2S active energy conforming to IEC 62053-22; Class 0.2 active energy conforming to ANSI C12.20; Class 0.2 active power conforming to IEC 61557-12; Class 0.5S reactive energy conforming to IEC 62053-24; Class 0.5 power factor conforming to IEC 61557-12; Class 0.2 voltage conforming to IEC 61557-12; Class 0.2 current conforming to IEC 61557-12
Number of outputs1 pulse
Information displayedVoltage; Current; Frequency; Power; Energy consumption; Harmonic distortion
Communication port protocolModbus RTU at 115 kbauds - 2-wire; ION at 115 kbauds - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; RSTP 801.1d 2004
Communication port supportETHERNET; Screw terminal block: RS485
Communication network typeIPv6 (internet protocol)
Data recordingMin/max of instantaneous values; Waveform logs; Sequence of event recording; Time stamping; Alarm logs; Trending/forecasting; Sag and swell logs; Harmonics logs; GPS synchronisation; Data logs; Event logs; 50 data recorders
Memory capacity512 MB
Web servicesCustomizable home page; File upload/download via FTP; File upload/download via SFTP; Web server; Alarm notification by e-mail; Viewing of captured waveform (FTP); Viewing of captured waveform (web); HTTPS server
Communication serviceSMTP e-mail notification; RSTP support; NTP time synchronization; DHCP; PTP time synchronization
CybersecurityEnable/disable communication ports; Password protection; Syslog protocol support; Robust security logs; Port hardening
mounting modeFlush-mounted
Mounting supportFramework
Installation categoryIII
Safety ConstructionIII400…690 V conforming to IEC 61010-1:ed. 3; III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
StandardsIEC 61557-12; IEC 62052-11; IEC 62053-24; IEC 62053-22; IEEE 1588; IEC 62586-2; IEC 61326-1
Product certificationsCE; CULus; N998
Width96 mm
Depth77.5 mm
Height96 mm
Product weight581 g
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Surge immunity test conforming to IEC 61000-4-5; Conducted RF disturbances conforming to IEC 61000-4-6; Magnetic field at power frequency conforming to IEC 61000-4-8; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Immunity to impulse waves conforming to IEC 61000-4-12; Conducted and radiated emissions conforming to EN 55022; Conducted and radiated emissions conforming to EN 55011; Conducted and radiated emissions conforming to FCC part 15; Conducted and radiated emissions conforming to ICES-003; Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579; Surge withstand conforming to IEEE C37.90.1
IP degree of protectionIP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529
Relative humidity5…95 %
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude3000 m
Compatibility codePM8240
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13.700 cm
Package 1 Width13.500 cm
Package 1 Length18.500 cm
Package 1 Weight840.500 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.124 kg
Country of originCA
Warranty (in months)18
Mounting methodFront mounting
ModelMeasurement transformer
Suitable forPurchase
Type of indicationDigital
Frequency45–67 Hz
Max. current (Imax)15 A
Number of positions total (counter)1
Type of meterElectronic
Degree of protection (IP)IP30
Type of interfaceRS-485
Energy typeEffective power and reactive power
Tariff typeOne-tariff
Tariff controlInternal
Escapement mechanismNo
CalibratedNo
ApprovalDomestic
Pulse outputElectrical
Pulse typeD0
Pole typeThree conductor/four conductor
Measurement type load profileYes
EEC40 signatureNo
With lock codeNo
Nominal voltage (Un) N-L0–347 V
Nominal voltage (Un) L-L0–600 V
Nominal current (In)5 A

Properties

MOQ1

Cross-References