| Manufacturer part number (MPN) | A9XMSB11 |
| EAN / GTIN | 3606480430602 |
| Sales unit | pcs |
| Package quantity | 32 pcs |
| Range of product | Acti9 |
| Product or component type | Smart communication module |
| Product name | EcoStruxure I/O Smart Link |
| Device short name | I/O Smart Link |
| Application type | Load control; Breaker status monitoring; Basic energy metering E |
| Number max of connected devices | Up to 11 wired devices |
| Group of channels | 1 group of 11 digital channels |
| Maximum supply current | 1.5 A |
| [Us] rated supply voltage | 24 V DC +/- 20 % |
| Connectivity to devices | Digital input and output; Pulse output meter |
| Communication service | Modbus server for RS485 |
| Web server | BMS controller compatible |
| Application specific I/O | Pulse totalising counter; Pulse converter |
| Protection type | Against reverse polarity for auxiliary supply; Against reverse polarity for input; Overvoltage at 33 V DC for digital output |
| Immunity to microbreaks | 10 ms |
| Reset | Factory reset on front face; By booted push-button; By address encoder; By plug in, plug out the power supply |
| Input/output type | 2 inputs + 1 output per digital channel |
| Input type | Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA |
| Maximum permanent current | 5 mA for digital input |
| Electronic filtering time | 2 ms for digital input from state 0 to state 1 |
| Output type | Logic current source: 24 V - DC - 100 mA |
| Maximum voltage drop | <1 V at state 1 digital output |
| Inrush current | 0.5 A for digital output; 7 A for power supply |
| Local signalling | Communication: 1 LED (yellow); Status: 1 LED (green, orange and red) |
| Type of setting | Modbus address 01...99 for address encoders; Reset for address encoders; Reset for plug in, plug out the auxiliary supply |
| Mounting position | Horizontal and vertical on DIN rail |
| Colour | White (RAL 9003) |
| Location of connection | Front |
| Connections - terminals | Spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately; Plug-in connector qty: 1 for supply circuit; Plug-in connector qty: 1 for communication bus |
| Clamping connection capacity | 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus; 1 x 0.2...1 x 1.5 mm², flexible with cable end for control; 1 x 0.2...1 x 1.5 mm², flexible without cable end for control; 1 x 0.2...1 x 1.5 mm², rigid with cable end for control; 1 x 0.2...1 x 1.5 mm², rigid without cable end for control; 2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit; 2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit; 2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit; 2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit |
| Wire stripping length | Control: 10 mm; Supply circuit: 7 mm; Communication bus: 7 mm |
| Communication network type | RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
| 9 mm pitches | 0 useful |
| Height | 22.5 mm |
| Width | 359 mm |
| Depth | 42 mm |
| Product weight | 188 g |
| Provided equipment | Set of 1 bus connector; Set of 1 power supply connector; Set of 2 locking clips |
| Range compatibility | Acti 9 iTL auxiliary; Linergy Linergy FM; Acti 9 iOF+SD 24; Acti 9 iACT24; Acti 9 iATL24; PowerLogic pulse output meter; Acti 9 RCA iC60; Acti 9 Acti9 iCT auxiliary; Acti 9 Acti9 iC60; Acti 9 Acti9 iID; Acti 9 Acti9 iSW-NA; Acti 9 Acti9 iDPN Vigi; Acti 9 Acti9 C40; Multi9 Multi9 C60; Acti 9 Acti9 DT40; Acti 9 Acti9 DT60; Acti 9 Acti9 I-NA; Acti 9 Acti9 ITG40; Acti 9 Acti9 iDPN; Acti 9 Acti9 Reflex iC60 Ti24 connector |
| Commissioning interface | EcoStruxure Power Commission |
| Market segment | Buildings; Small commercial |
| Compatibility code | Acti 9 Smartlink |
| IP degree of protection | IP20 |
| IK degree of protection | IK06 conforming to IEC 62262 |
| Pollution degree | 3 |
| Electromagnetic compatibility | Resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2; Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2; Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3; Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3; Power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4; Input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4; Communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4; Conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6; Conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1; Conducted emission (0.15...30 MHz), class B, conforming to CISPR 11; Radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1; Radiated emission (30...6000 MHz), class B, conforming to CISPR 11; Power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5; Power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5; Communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5 |
| Environmental characteristic | Corrosive 3C2 conforming to IEC 60721-3-3; Salt mist 2 conforming to IEC 60068-2-52 |
| Vibration resistance | 1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Fire resistance | Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10; On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10 |
| Tropicalisation | 2 |
| Relative humidity | 0…93 % at 40 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Standards | IEC 61010-2-201; IEC 61010-1 |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 32 |
| Country of origin | FR |
| Warranty (in months) | 18 |
| Analogue inputs configurable | Yes |
| Analogue outputs configurable | No |
| Number of digital inputs | 22 |
| Number of digital outputs | 11 |
| Digital inputs configurable | Yes |
| Digital outputs configurable | Yes |
| Supply voltage DC | 24 V |
| Voltage type (supply voltage) | DC |
| Input current at signal 1 | 2.5 mA |
| Permitted voltage at input | 19.2–28.8 V |
| Type of voltage (input voltage) | DC |
| Output current at digital output | 0.1 A |
| Output voltage at digital output | 24 V |
| Type of output voltage | DC |
| Short-circuit protection, digital outputs available | Yes |
| Analogue input, current | No |
| Analogue input, voltage | No |
| Analogue input, resistor | No |
| Analogue input, resistor temperature | No |
| Analogue input, thermocouple | No |
| Analogue input signal configurable | No |
| Number of HW-interfaces RS-485 | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Degree of protection (IP) | IP20 |
| Type of electric connection | Plug-in connection |
| Fieldbus connection over separate bus coupler possible | No |
| Suitable for rail mounting | No |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | No |
| Rack-assembly possible | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Suitable for safety functions | No |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |