| Manufacturer part number (MPN) | STBEHC3020KC |
| EAN / GTIN | 3595863933116 |
| Sales unit | pcs |
| Package quantity | 30 pcs |
| Range of product | Modicon STB distributed I/O solution |
| Product or component type | Counter kit |
| Number of channels | 1 |
| Kit composition | STBEHC3020 module; STBXBA3000 base; STBXTS215018 terminal spring clamp connector |
| Counting input number | 2 |
| Maximum counting frequency | 40000 Hz |
| Counter functions | Measure time periods; Up/down counting; Down counting; Frequency meter; Loop (modulo) counting; Count events |
| Counter configuration | Modicon configuration software |
| Input compatibility | 2/3 wire photo-electric sensor; Mechanical contact; With 2-wire/3-wire proximity sensors; Incremental encoder |
| input voltage | 24 V |
| Input voltage limits | 19.2...30 V |
| Input voltage type | DC |
| Input current | 6 mA |
| Input logic | Positive |
| Voltage state 0 guaranteed | -3...5 V |
| Voltage state 1 guaranteed | 11...30 V |
| Current state 0 guaranteed | <= 1.5 mA |
| Current state 1 guaranteed | >= 2 mA |
| Filter time | 0 ms digital 40000 Hz counting inputs; 0.4 ms digital 1000 Hz counting inputs; 1.2 ms digital 400 Hz counting inputs; 2.5 µs analog counting inputs; 25 µs analog auxiliary input |
| output voltage | 24 V |
| Output voltage limits | 19.2...30 V |
| Output voltage type | DC |
| nominal output current | 0.5 A |
| Discrete output logic | Positive or negative configurable |
| Maximum leakage current | 0.1 mA at state 0 |
| Maximum voltage drop | <3 V at state 1 |
| Maximum load inductance | 500 mH at 4 Hz |
| Protection type | Overload protection electronic tripping manual or automatic reset; Short-circuit protection electronic tripping manual or automatic reset; Overload protection current limiter; Short-circuit protection current limiter |
| Fallback status | Hold last value configured; State 0 for output channels by default; State 0 or 1 for each channel configured |
| Cold swapping | Yes |
| Hot swapping fallback | Fallback output depending on parameter setting configured mandatory standard network interface module; Fallback to 0 not configured mandatory standard network interface module; Fallback to 0 basic network interface module |
| Product compatibility | Mounting base STBXBA3000; Power distribution module STBPDT3100/3105 |
| [Us] rated supply voltage | 24 V DC |
| Supply | Power distribution module |
| Current consumption | 60...100 mA at 5 V DC for logic bus |
| Insulation between channels and bus | 500 V |
| Marking | CE |
| Overvoltage category | II |
| Status LED | 1 LED (green) EN validation input status (EN); 1 LED (green) module status (RDY); 1 LED (green) reset input status (RST); 1 LED per counting input (green) counting input status (INA, INB); 1 LED per output (green) output status (OUT1, OUT2); 1 LED (red) module error (FLT) |
| Height | 28.1 mm |
| Depth | 70 mm |
| Width | 128.3 mm |
| DC supply voltage | 24 V |
| Product certifications | FM Class 1 Division 2; CSA; UL |
| Pollution degree | 2 conforming to IEC 60664-1 |
| Operating altitude | <= 2000 m |
| IP degree of protection | IP20 conforming to IEC 61131-2 class 1 |
| Ambient air temperature for operation | -25…70 °C (without derating) |
| Ambient air temperature for storage | -40…85 °C |
| Relative humidity | 95 % at 60 °C without condensation |
| Vibration resistance | 3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail; 5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail; +/-0.35 mm at 10…58 Hz |
| Shock resistance | 30 gn for 11 ms conforming to IEC 88 reference 2-27 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.400 cm |
| Package 1 Width | 8.000 cm |
| Package 1 Length | 13.200 cm |
| Package 1 Weight | 163.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 3.763 kg |
| Country of origin | ID |
| Warranty (in months) | 18 |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 24 V |
| Voltage type (supply voltage) | AC/DC |
| Number of functions | 6 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | No |
| Suitable for counting | No |
| Suitable for weighing | No |
| Suitable for temperature control | No |
| Suitable for welding control | No |
| Suitable for pressure control | No |
| Suitable for NC | No |
| Suitable for electronic positioning | No |
| Suitable for CNC | No |
| Suitable for SSI | No |
| Suitable for incremental data detection | No |
| Suitable for detection absolute value | No |
| Suitable for flux controller | No |
| Suitable for flux measurement | No |
| Suitable for path controller | No |
| Suitable for cam controller | No |
| Suitable for multi-axis control | No |
| Suitable for single-axis controller | No |
| Suitable for multi-axis positioning | No |
| Suitable for single-axis positioning | No |
| Function block restart blockage | No |
| Function block automatic reset | No |
| Contactor control function block | No |
| Function block emergency stop | No |
| Function block contactless working protection installation | No |
| Function block affirm push button | No |
| Function block 2-hand switching | No |
| Function block operating mode selection | No |
| Function block access control | No |
| Degree of protection (IP) | IP20 |
| Fieldbus connection over separate bus coupler possible | No |
| Frequency measurement | No |
| Suitable for rail mounting | No |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |