cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric redundant power supply module X80 - 100..240 V AC - Safety BMXCPS4002S

Schneider Electric · Switchgear & Protection · DIN Rail Power Supplies · France · se.com
Part Number
BMXCPS4002S  ·  HS 8504.40
Schneider Electric redundant power supply module X80 - 100..240 V AC - Safety BMXCPS4002S

Schneider Electric BMXCPS4002S Modicon X80 - alim sécurité redondante - 40W 110/220Vac - fonctions prédictive.

Technical Specifications

Manufacturer part number (MPN)BMXCPS4002S
EAN / GTIN3606481204950
Sales unitpcs
Package quantity6 pcs
Range of productModicon X80
Product or component typePower supply module
backplane compatibilityAll backplane
advanced diagnostics available via networkRedundancy information; Redundancy test; Temperature sensing; Remaining lifetime; Uptime duration
Primary voltage100...240 V
Supply circuit typeAC
Secondary power15 W 3.3 V DC at -25…60 °C I/O module logic power supply; 40 W 24 V DC at -25…60 °C I/O module power supply and processor if 3.3 V not loaded
Primary voltage limit85...264 V
Network frequency50/60 Hz
Network frequency limits47…63 Hz
Apparent power0.13 kVA
Input current0.55 A 230 V; 1.1 A 115 V
Inrush current30 A 115 V; 60 A 230 V
I²t on activation1 A².s 115 V; 4 A².s 230 V
It on activation0.1 A.s 115 V; 0.15 A.s 230 V
MTBF reliability792000 H
Protection typeInternal fuse not accessible for primary circuit; Overload protection for secondary circuit; Overvoltage protection for secondary circuit; Short-circuit protection for secondary circuit
Current at secondary voltage4.5 A 3.3 V DC I/O module logic power supply; 1.67 A 24 V DC I/O module power supply and processor
Maximum power dissipation in W8.5 W
Status LED1 LED (green) presence of voltages (OK); 1 LED (green) redundancy OK; 1 LED (green) power supply status
Control typeRESET push-button cold restart
Electrical connection1 connector 2 pin(s)alarm relay; 1 connector 5 pin(s)line supply, protective earth
Insulation resistance>= 100 MOhm primary/ground; >= 100 MOhm primary/secondary
Product weight0.51 kg
Immunity to microbreaks10 ms
Dielectric strength1500 V primary/secondary I/O module logic power supply; 1500 V primary/secondary I/O module power supply and processor; 2300 V primary/secondary sensor power supply; 1500 V primary/ground; 500 V 24 V sensor output/ground
Vibration resistance3 gn
Shock resistance15 gn
IP degree of protectionIP20
Directives2014/30/EU - electromagnetic compatibility; 2006/42/EC - machinery; 2014/34/EU - ATEX directive
Product certificationsCE; UL; CSA; RCM; EAC; Merchant Navy; ATEX zone 2/22; IECEx zone 2/22; TÜV
StandardsIEC 61131-2; IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201; IACS E10; EN/IEC 61000-6-5, interface type 1 and type 2; EN/IEC 61850-3, location G; IEC 60079-0
Environmental characteristicHazardous location class I division 2; Gas resistant class Gx conforming to ISA S71.04; Gas resistant class 3C4 conforming to IEC 60721-3-3; Dust resistant class 3S4 conforming to IEC 60721-3-3; Sand resistant class 3S4 conforming to IEC 60721-3-3; Salt resistant level 2 conforming to IEC 68252; Mold growth resistant class 3B2 conforming to IEC 60721-3-3; Fungal spore resistant class 3B2 conforming to IEC 60721-3-3
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…60 °C
Relative humidity5…95 % at 55 °C without condensation
Protective treatmentConformal coating
Operating altitude0...2000 m; 2000...5000 m with derating factor
Number of Units in Package 11
Number of Units in Package 26
Country of originID
Warranty (in months)18
Width68 mm
Height100 mm
Depth150 mm
Suitable for safety functionsYes
Type of voltage (input voltage)AC/DC
Power output40 W
RedundancyYes
Output voltage AC 50 Hz3.3–24 V
Output voltage AC 60 Hz3.3–24 V
Input voltage AC 50 Hz100–240 V
Input voltage AC 60 Hz100–240 V
Max. output current AC 50 Hz4.5 A
Max. output current AC 60 Hz4.5 A
Max. output current DC4.5 A
Max. input current AC 50 Hz1.1 A
Max. input current AC 60 Hz1.1 A
Type of output voltageAC/DC

Properties

MOQ1

Cross-References

Attached Documents