Schneider Electric Modicon TM3 - 2 analog or temperature inputs, 1 analog output (screw) 24VDC TM3TM3

Schneider Electric · Control & Automation · PLCs · France · se.com
Part Number
TM3TM3  ·  HS 8538.90
Schneider Electric Modicon TM3 - 2 analog or temperature inputs, 1 analog output (screw) 24VDC TM3TM3

Schneider Electric TM3TM3 Accessories Modicon PLS - IO extension - 2 temperaturinnganger and 1 analog output.

Technical Specifications

Manufacturer part number (MPN)TM3TM3
EAN / GTIN3606480649042
Sales unitpcs
Package quantity42 pcs
Range of productModicon TM3
Product or component typeInput/output analog module
Range compatibilityModicon M221; Modicon M241; Modicon M251; Modicon M262
Analogue input number2
Analogue output number1
Analogue input typeCurrent 4...20 mA; Current 0...20 mA; Voltage 0...10 V; Voltage - 10...10 V; Thermocouple - 200...1000 °C thermocouple J; Thermocouple - 200...1300 °C thermocouple K; Thermocouple 0...1760 °C thermocouple R; Thermocouple 0...1760 °C thermocouple S; Thermocouple 0...1820 °C thermocouple B; Thermocouple - 200...400 °C thermocouple T; Thermocouple - 200...1300 °C thermocouple N; Thermocouple - 200...800 °C thermocouple E; Thermocouple 0...2315 °C thermocouple C; Temperature probe - 60...180 °C Ni 100/Ni 1000; Temperature probe - 200...850 °C Pt 100; Temperature probe - 200...600 °C Pt 1000
Analogue input resolution16 bits; 15 bits + sign
Permissible continuous overload13 V, analogue input type: voltage; 40 mA, analogue input type: current
Stabilisation time1 ms
Input impedance= 1 MOhm
Sampling duration10 ms
Analogue output typeCurrent: 4...20 mA; Current: 0...20 mA; Voltage: 0...10 V; Voltage: - 10...10 V
Conversion time100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
Absolute accuracy error+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C; +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C; +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C; +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C; +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C; +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C; +/- 0.1 % of full scale at 25 °C for analogue input voltage/current; +/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C; +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe; +/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C; +/- 0.1 % of full scale at 25 °C for thermocouple B 300...1820 °C; +/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C; +/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C; +/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C; +/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C; +/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C; +/- 0.1 % of full scale at 25 °C for analogue output voltage/current
Repeat accuracy+/-0.5 %FS for input
Output ripple20 mV
Cross talk<= 1 LSB
Type of cableTwisted shielded pairs cable <30 m for input/output circuit
Electrical connection11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
LSB value0.15 mV, 0...10 V; 0.30 mV, - 10...10 V; 0.30 µA, 0...20 mA; 0.244 µA, 4...20 mA; 0.1 °C; 2.44 mV, 0...10 V; 4.88 mV, - 10...10 V; 4.88 µA, 0...20 mA; 3.91 µA, 4...20 mA
InsulationBetween input and supply at 1500 V AC; Between input and internal logic at 500 V AC; Between output and supply at 1500 V AC; Between output and internal logic at 500 V AC
Immunity to microbreaks10 ms
Load impedance ohmic1 kOhm voltage; 300 Ohm current
load typeResistive
Temperature drift+/- 0.006 %FS/°C
Non-linearity+/- 0.01 %FS, analogue output type: analog output; +/- 0.1 %FS, analogue input type: analog input
Typical current consumption55 mA at 24 V DC no load; 55 mA at 5 V DC no load; 60 mA at 5 V DC full load; 80 mA at 24 V DC full load
Local signalling1 LED green for PWR
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit
Height90 mm
Width23.6 mm
Depth70 mm
Product weight0.115 kg
IP degree of protectionIP20
MarkingCE
Product certificationsCE; UKCA; RCM; EAC; CULus; CULus HazLoc
StandardsIEC 61131-2
Electromagnetic emissionRadiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to IEC 55011
Ambient air temperature for operation-10…55 °C (horizontal installation); -10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 % without condensation
Operating altitude0...2000 m
Pollution degree2
Vibration resistance3.5 mm (f = 5…8.4 Hz) on DIN rail; 3 gn (f = 8.4…150 Hz) on DIN rail
Shock resistance15 gn for 11 ms
Number of Units in Package 11
Number of Units in Package 242
Number of Units in Package 3504
Country of originJP
Warranty (in months)18
Power consumption1.1 W
Number of analogue inputs2
Number of analogue outputs1
Analogue inputs configurableYes
Analogue outputs configurableNo
Input, currentYes
Input, voltageYes
Input, resistorYes
Input, resistance thermometerNo
Input, thermocoupleYes
Input signal, configurableNo
Resolution of the analogue inputs16 Bit
Output, currentYes
Output, voltageYes
Output signal configurableNo
Resolution of the analogue outputs12 Bit
Type of electric connectionScrew connection
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone