cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric distributed analog output Modicon Momentum - 4 Output - 4..20 mA 170AAO92100

Schneider Electric · Control & Automation · PLCs & Industrial Networking · France · se.com
Part Number
170AAO92100  ·  HS 8538.90
Schneider Electric distributed analog output Modicon Momentum - 4 Output - 4..20 mA 170AAO92100

Schneider Electric distributed analog output Modicon Momentum - 4 Output - 4.20 mA.

Technical Specifications

Manufacturer part number (MPN)170AAO92100
EAN / GTIN3595861147720
Sales unitpcs
Package quantity10 pcs
Output signal4–20 mA
Range of productModicon Momentum automation platform
Product or component typeAnalogue output base
Analogue output number4
Data formatFull 16 bits signed
Analogue output range+/- 10 V 12 bits + sign >= 1 kOhm; 4...20 mA 12 bits + sign <= 0.6 kOhm
Maximum load capacitance1 µF
Absolute accuracy error+/- 0.2 % of full scale +/- 10 V 25 °C; +/- 0.25 % full scale +/- 10 V 60 °C; +/- 0.4 % of full scale 4...20 mA 25 °C; +/- 0.5 % of full scale 4...20 mA 60 °C
Update time2 ms
Full scale10 V +/- 10 V; 2 mA 4...20 mA
Fail stateHold; Reset to full scale; Reset to zero
Protection typeInternal 2 A slow-blow
Output short-circuit protectionWith in voltage circuit
External power requirement+/- 30 V DC; 24 V DC
Permissible common mode voltage250 V 47...63 Hz AC between channels to ground; 250 V 47...63 Hz DC
Reverse polarity protectionInternal
Module formatStandard
Temperature drift10 %oFS/°C; 30 %oFS/°C
Typical current consumption150 mA at 24 V DC; 530 mA at 24 V DC
Power dissipation in W8.5 W
Isolation between channels and ground500 V AC
Local signalling4 LEDs for channel status
Height125 mm
Width141.5 mm
Depth47.5 mm
Product weight0.215 kg
Protective treatmentTC
MarkingCE
Product certificationsUL; CSA
Ambient air temperature for operation0…60 °C
Ambient air temperature for storage-40…85 °C
Relative humidity95 % without condensation
Operating altitude<= 5000 m
Number of Units in Package 11
Number of Units in Package 210
Number of Units in Package 380
Country of originID
Warranty (in months)18
Power consumption8.5 W
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC24 V
Voltage type (supply voltage)DC
Input, currentNo
Input, voltageNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableNo
Output, currentYes
Output, voltageYes
Output signal configurableYes
Resolution of the analogue outputs12 Bit
Number of analogue outputs4
Analogue inputs configurableNo
Analogue outputs configurableYes
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryNo
Fieldbus connection over separate bus coupler possibleNo
Suitable for rail mountingNo
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone

Properties

MOQ1

Cross-References

Attached Documents