| Manufacturer part number (MPN) | 170AAO92100 |
| EAN / GTIN | 3595861147720 |
| Sales unit | pcs |
| Package quantity | 10 pcs |
| Output signal | 4–20 mA |
| Range of product | Modicon Momentum automation platform |
| Product or component type | Analogue output base |
| Analogue output number | 4 |
| Data format | Full 16 bits signed |
| Analogue output range | +/- 10 V 12 bits + sign >= 1 kOhm; 4...20 mA 12 bits + sign <= 0.6 kOhm |
| Maximum load capacitance | 1 µF |
| Absolute accuracy error | +/- 0.2 % of full scale +/- 10 V 25 °C; +/- 0.25 % full scale +/- 10 V 60 °C; +/- 0.4 % of full scale 4...20 mA 25 °C; +/- 0.5 % of full scale 4...20 mA 60 °C |
| Update time | 2 ms |
| Full scale | 10 V +/- 10 V; 2 mA 4...20 mA |
| Fail state | Hold; Reset to full scale; Reset to zero |
| Protection type | Internal 2 A slow-blow |
| Output short-circuit protection | With in voltage circuit |
| External power requirement | +/- 30 V DC; 24 V DC |
| Permissible common mode voltage | 250 V 47...63 Hz AC between channels to ground; 250 V 47...63 Hz DC |
| Reverse polarity protection | Internal |
| Module format | Standard |
| Temperature drift | 10 %oFS/°C; 30 %oFS/°C |
| Typical current consumption | 150 mA at 24 V DC; 530 mA at 24 V DC |
| Power dissipation in W | 8.5 W |
| Isolation between channels and ground | 500 V AC |
| Local signalling | 4 LEDs for channel status |
| Height | 125 mm |
| Width | 141.5 mm |
| Depth | 47.5 mm |
| Product weight | 0.215 kg |
| Protective treatment | TC |
| Marking | CE |
| Product certifications | UL; CSA |
| Ambient air temperature for operation | 0…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Relative humidity | 95 % without condensation |
| Operating altitude | <= 5000 m |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 10 |
| Number of Units in Package 3 | 80 |
| Country of origin | ID |
| Warranty (in months) | 18 |
| Power consumption | 8.5 W |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 24 V |
| Voltage type (supply voltage) | DC |
| Input, current | No |
| Input, voltage | No |
| Input, resistor | No |
| Input, resistance thermometer | No |
| Input, thermocouple | No |
| Input signal, configurable | No |
| Output, current | Yes |
| Output, voltage | Yes |
| Output signal configurable | Yes |
| Resolution of the analogue outputs | 12 Bit |
| Number of analogue outputs | 4 |
| Analogue inputs configurable | No |
| Analogue outputs configurable | Yes |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | No |
| Fieldbus connection over separate bus coupler possible | No |
| Suitable for rail mounting | No |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |