cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric distributed analog/discrete I/O Modicon Momentum 170AMM09000

Schneider Electric · Control & Automation · PLCs & Industrial Networking · France · se.com
Part Number
170AMM09000  ·  HS 8538.90
Schneider Electric distributed analog/discrete I/O Modicon Momentum 170AMM09000

Schneider Electric 170AMM09000 4/2 In/out, 4/2 In/out Ana.

Technical Specifications

Manufacturer part number (MPN)170AMM09000
EAN / GTIN3595861000292
Sales unitpcs
Package quantity4 pcs
Range of productModicon Momentum automation platform
Product or component typeAnalogue,discrete I/O base
Group of channels1 group of 2 discrete outputs; 1 group of 4 discrete inputs; 1 group of 4 analog differential inputs; 1 group of 2 analog outputs
Analogue output range+/- 10 V 12 bits; 0...20 mA 12 bits
Output short-circuit protectionWith discrete output
Output overload protectionWith discrete output
Discrete input number4
Conversion consistency+/- 0.02 % +/- 10 V analogue input circuit; +/- 0.04 % +/- 20 mA analogue input circuit; +/- 0.04 % +/- 5 V analogue input circuit; +/- 0.04 % 1...5 V analogue input circuit; +/- 0.04 % 4...20 mA analogue input circuit
Current state 0 guaranteed<= 1.2 mA (discrete input)
Current state 1 guaranteed>= 2.5 mA (discrete input)
Input overvoltage protection-50…50 V <= 100 s analogue input circuit; -30…30 V 24 V analogue input circuit
Input resistance1 MOhm analogue input circuit; 4 kOhm discrete input
Output load= 3 kOhm +/- 10 V analogue output
Conversion error+/- 0.35 % +/- 10 V 25 °C analogue output; +/- 0.35 % 0...20 mA 25 °C analogue output; +/- 0.70 % +/- 10 V 60 °C analogue output; +/- 0.70 % 0...20 mA 60 °C analogue output; 0,0008 +/- 10 V 25 °C analogue input circuit; 0,0015 +/- 10 V 60 °C analogue input circuit; 0,0016 +/- 20 mA 25 °C analogue input circuit; 0,0016 +/- 5 V 25 °C analogue input circuit; 0,0016 1...5 V 25 °C analogue input circuit; 0,0016 4...20 mA 25 °C analogue input circuit; 0,003 +/- 20 mA 60 °C analogue input circuit; 0,003 +/- 5 V 60 °C analogue input circuit; 0,003 1...5 V 60 °C analogue input circuit; 0,003 4...20 mA 60 °C analogue input circuit
Fail stateFor analogue input circuit: hold; For analogue input circuit: reset to zero
Maximum voltage drop<0.5 V 1 A at state on discrete output
Operating rate100 cyc/s resistive 1 A discrete output; 1000 cyc/h inductive 1 A discrete output; 8 cyc/s tungsten <2.4 W discrete output
Isolation voltage500 V (duration = 1 min) between analogue I/O and operating voltage; 500 V (duration = 1 min) between operating voltage and I/O from ground
Discrete input voltage24 V DC
Discrete input logicPositive
Voltage state 0 guaranteed-3...5 V
Voltage state 1 guaranteed11...24 V
Analogue input typeDifferential, input range: +/- 10 V; Differential, input range: +/- 20 mA; Differential, input range: +/- 5 V; Differential, input range: 1...5 V; Differential, input range: 4...20 mA
Analogue input resolution12 bits; 13 bits; 14 bits
Common mode rejection> 54 dB for analogue input circuit
Input voltage limits< 30 V
Discrete output logicPositive
Discrete output current1 A per point; 2 A per group; 2 A per module
Maximum leakage current1 mA for discrete output
Conversion time<= 1 ms for analog output; 10 ms for analogue input circuit
Analogue output resolution12 bits, +/- 10 V; 12 bits, 0...20 mA
Response time< 0.1 ms from state 0 to state 1 for discrete output; < 0.1 ms from state 1 to state 0 for discrete output; 2.2 ms from state 0 to state 1 for discrete input; 3.3 ms from state 1 to state 0 for discrete input
[Us] rated supply voltage24 V DC
Local signalling8 LEDs for channel status
Current consumption<= 350 mA at 24 V DC; 200 mA at 24 V DC
Maximum power dissipation in W6 W
Height125 mm
Width141.5 mm
Depth47.5 mm
Protective treatmentTC
MarkingCE
Product certificationsUL; CSA; FM Class 1 Division 2
Ambient air temperature for operation0…60 °C
Ambient air temperature for storage-40…85 °C
Relative humidity0…95 % without condensation
Operating altitude<= 5000 m
Number of Units in Package 11
Number of Units in Package 210
Country of originID
Warranty (in months)18
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Number of analogue inputs5
Number of analogue outputs2
Analogue inputs configurableNo
Analogue outputs configurableNo
Number of digital inputs4
Number of digital outputs1
Digital inputs configurableNo
Digital outputs configurableNo
Supply voltage DC24 V
Voltage type (supply voltage)DC
Input current at signal 120 mA
Permitted voltage at input-10–10 V
Type of voltage (input voltage)DC
Output current at digital output0.02 A
Output voltage at digital output-10–10 V
Type of output voltageDC
Short-circuit protection, digital outputs availableYes
Analogue input, currentNo
Analogue input, voltageYes
Analogue input, resistorNo
Analogue input, resistor temperatureNo
Analogue input, thermocoupleNo
Resolution of the analogue inputs12 Bit
Analogue input signal configurableNo
Analogue output, currentYes
Analogue output, voltageYes
Resolution of the analogue outputs12 Bit
Analogue output signal configurableNo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryNo
Time delay at signal change10 ms
Fieldbus connection over separate bus coupler possibleNo
Suitable for rail mountingNo
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Suitable for safety functionsNo
Appendant operation agent (Ex ia)No

Properties

MOQ1

Cross-References