| Manufacturer part number (MPN) | XACB4933 |
| EAN / GTIN | 3389110423976 |
| Sales unit | pcs |
| Contact configuration | 3 NC |
| Range of product | Harmony XAC |
| Product or component type | Pendant control station |
| Device short name | XACB |
| Control station type | Double insulated |
| Enclosure material | Glass reinforced polyester |
| Electrical circuit type | Power circuit |
| enclosure type | Complete ready for use |
| Control station application | Control of single speed hoist motor |
| Control station composition | 4 push-buttons + 1 emergency stop |
| Control button type | Stop push-button Ø 40 mm 3 NC latching; First push-button 3-pole raise, slow; Second push-button 3-pole lower, slow; Fourth push-button 3-pole left, slow; Third push-button 3-pole right, slow |
| Product compatibility | XESD2201 for reversing operation; XACS499 for emergency stop |
| Mechanical interlocking | With mechanical interlocking between pairs |
| Control station colour | Yellow |
| Connections - terminals | Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end |
| Standards | IEC 60204-32; CSA C22.2 No 14; IEC 60947-5-1 |
| Product certifications | CSA type 4 |
| Protective treatment | TH |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
| Overvoltage category | Class II conforming to IEC 61140 |
| IP degree of protection | IP65 conforming to IEC 60529 |
| Mechanical durability | 1000000 cycles |
| Cable entry | Rubber sleeve with stepped entry 10…22 mm |
| [Ithe] conventional enclosed thermal current | 20 A |
| [Ui] rated insulation voltage | Emergency stop contact: 400 V (pollution degree 3) conforming to IEC 60947-1; 300 V conforming to CSA |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Contact operation | Snap action |
| Operating force | 32 N push-button; 40 N emergency stop |
| Short-circuit protection | 12 A fuse protection by cartridge fuse type aM |
| Rated power in hp | 3 hp at 240 V |
| Rated operational power in W | 3000 W at 240 V; 3000 W at 400 V |
| Electrical durability | 1000000 cycles AC-3, 3000 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A; 1000000 cycles AC-4, 3000 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A; 700000 cycles AC-3, 3000 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A; 700000 cycles AC-4, 3000 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A |
| Terminals description ISO n°1 | (33-34)NO; (23-24)NO; (13-14)NO; (53-54)NO; (73-74)NO; (63-64)NO |
| Terminals description ISO n°2 | (31-32)NC; (21-22)NC; (11-12)NC |
| Terminal identifier | (11-12)NC; (13-14)NO |
| Product weight | 1.39 kg |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.200 cm |
| Package 1 Width | 11.400 cm |
| Package 1 Length | 70.300 cm |
| Package 1 Weight | 1.892 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 72.500 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 37.000 kg |
| Country of origin | CZ |
| Warranty (in months) | 18 |
| Width | 98 mm |
| Height | 499 mm |
| Depth | 83 mm |
| Number of command positions | 4 |
| Colour housing cover | Yellow |
| Suitable for emergency stop | No |
| Housing material | Plastic |
| Number of speeds | 1 |
| Type of executable motions | Transport - hoist |
| Degree of protection (IP) | IP65 |