Schneider Electric pendant control station XAC-A - 2 pushbuttons 1 Emergency stop XACA2713

Schneider Electric · Control & Automation · Pushbuttons & Pilot Lights · France · se.com
Part Number
XACA2713  ·  HS 8537.10
Schneider Electric pendant control station XAC-A - 2 pushbuttons 1 Emergency stop XACA2713

Schneider Electric XACA2713.

Technical Specifications

Manufacturer part number (MPN)XACA2713
EAN / GTIN3389110426809
Sales unitpcs
Contact configuration1 NO
Range of productHarmony XAC
Product or component typePendant control station
Device short nameXACA
Control station typeDouble insulated
Enclosure materialPolypropylene
Electrical circuit typeControl circuit
enclosure typeComplete ready for use
Control station applicationControl of single speed hoist motor
Control station composition2 push-buttons + 1 emergency stop
Control button typeFirst push-button 1 NO raise, slow; Second push-button 1 NO lower, slow; Stop push-button Ø 30 mm 1 NC latching
Product compatibilityZB2BE101 for each direction; ZB2BE102 for emergency stop
Mechanical interlockingWith mechanical interlocking
Control station colourYellow
Connections - terminalsScrew clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end; Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
StandardsIEC 60947-5-1; IEC 60204-32; CSA C22.2 No 14; UL 508
Product certificationsCCC; GOST
Protective treatmentTH
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…70 °C
Vibration resistance15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance100 gn conforming to IEC 60068-2-27
Overvoltage categoryClass II conforming to IEC 61140
IP degree of protectionIP65 conforming to IEC 60529
IK degree of protectionIK08 conforming to IEC 62262
Mechanical durability1000000 cycles
Cable entryRubber sleeve with stepped entry 8…26 mm
Contact code designationA600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A; Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A; Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage600 V (pollution degree 3)
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Contact operationSlow-break
Maximum resistance across terminals25 MOhm
Operating force10 N push-button; 8 N emergency stop
Short-circuit protection10 A fuse protection by cartridge fuse type gG
Rated operational power in W40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Terminals description ISO n°1(13-14)NO
Terminals description ISO n°2(11-12)NC
Terminal identifier(13-14)NO; (11-12)NC
Product weight0.575 kg
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.000 cm
Package 1 Width12.000 cm
Package 1 Length52.500 cm
Package 1 Weight625.000 g
Unit Type of Package 2S06
Number of Units in Package 230
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight32.050 kg
Country of originCZ
Warranty (in months)18
Width80 mm
Height314 mm
Depth107 mm
Number of command positions2
Colour housing coverYellow
Suitable for emergency stopYes
Housing materialPlastic
Number of speeds1
Type of executable motionsLift
Degree of protection (IP)IP65
Rated operation current Ie at AC-15, 600 V1.2 A

Properties

MOQ1

Cross-References