| Manufacturer part number (MPN) | TPRAN2X1 |
| EAN / GTIN | 3606489832902 |
| Sales unit | pcs |
| Package quantity | 16 pcs |
| Range | TeSys |
| Product name | TeSys island |
| Device short name | TPRAN |
| Product or component type | Analog IO module |
| Device presentation | IO module providing 2 analog inputs and 1 analog output; Enabling advanced control functions in a TeSys island system; Operational only when connected to a bus coupler TPRBC |
| Function of module | Measurement of voltage, current or temperature on 2 configurable analog inputs; Driving voltage or current source on 1 configurable analog output |
| Product compatibility | TPRBC bus coupler |
| Analogue input number | 2 isolated with common point |
| Analogue input type | Current 4...20 mA; Current 0...20 mA; Voltage 0...10 V; Voltage - 10...10 V; Temperature probe - 60...180 °C temperature probe: Ni 100; Temperature probe - 60...180 °C temperature probe: Ni 1000; Temperature probe -200...+850 °C temperature probe: Pt 100; Temperature probe - 200...600 °C temperature probe: Pt 1000; Thermocouple - 200...1000 °C thermocouple J; Thermocouple - 200...1300 °C thermocouple K; Thermocouple 0...1760 °C thermocouple R; Thermocouple 0...1760 °C thermocouple S; Thermocouple 0...1820 °C thermocouple B; Thermocouple - 200...400 °C thermocouple T; Thermocouple - 200...1300 °C thermocouple N; Thermocouple - 200...800 °C thermocouple E; Thermocouple 0...2315 °C thermocouple C |
| Measurement accuracy | +/- 0.1 % of full scale voltage 25 °C; +/- 0.1 % of full scale current 25 °C; +/- 0.1 % of full scale temperature probe 25 °C; +/- 0.1 % of full scale in positive temperature range thermocouple 25 °C; +/- 0.4 % of full scale in negative temperature range thermocouple 25 °C |
| Analogue input resolution | 15 bits + sign full scale |
| Input impedance | = 1 MOhm voltage; >= 1 MOhm thermocouple; >= 1 MOhm temperature probe |
| Analogue output number | 1 isolated |
| Analogue output type | Current 4...20 mA; Current 0...20 mA; Voltage 0...10 V; Voltage - 10...10 V |
| Analogue output resolution | 12 bits, 4...20 mA full scale; 12 bits, 0...20 mA full scale; 12 bits, 0...10 V full scale; 11 bits + sign, - 10...10 V full scale |
| Type of cable | Twisted shielded pairs cable <30 m for input/output circuit |
| Local signalling | 1 LED (green/red) for DS (device status) |
| [Us] rated supply voltage | 24 V DC supplied by the bus coupler |
| Current consumption | 160 mA |
| Power dissipation in W | 0.5 W maximum |
| [Uimp] rated impulse withstand voltage | 0.5 kV conforming to IEC 61010-1 |
| Standards | IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201 |
| Product certifications | CSA; UL; EAC (pending) |
| Mounting mode | Horizontal and vertical (35 mm symmetrical rail) |
| Connections - terminals | Input/output circuit: removable spring terminal block 8 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) rigid; Input/output circuit: removable spring terminal block 8 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Input/output circuit: removable spring terminal block 8 cable(s) 0.25…2.5 mm² (22 AWG...14 AWG) flexible with cable end |
| Width | 25 mm |
| Height | 118 mm |
| Depth | 114 mm |
| Product weight | 0.172 kg |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -10…60 °C |
| Relative humidity | 5…95 % |
| Operating altitude | 0...2000 m without derating |
| IP degree of protection | IP20 |
| Pollution degree | 2 |
| Protective treatment | TC |
| Fire resistance | 960 °C conforming to UL 94 |
| Shock resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Electromagnetic compatibility | Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4; Surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 13.500 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 245.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.654 kg |
| Country of origin | ID |
| Warranty (in months) | 18 |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Voltage type (supply voltage) | DC |
| Input, current | Yes |
| Input, voltage | Yes |
| Input, resistor | No |
| Input, resistance thermometer | Yes |
| Input, thermocouple | Yes |
| Input signal, configurable | Yes |
| Resolution of the analogue inputs | 16 Bit |
| Output, current | Yes |
| Output, voltage | Yes |
| Output signal configurable | Yes |
| Resolution of the analogue outputs | 12 Bit |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 1 |
| Analogue inputs configurable | Yes |
| Analogue outputs configurable | Yes |
| Number of HW-interfaces other | 2 |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Degree of protection (IP) | IP20 |
| Type of electric connection | Plug-in connection |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |