| Manufacturer part number (MPN) | TPRDG4X2 |
| EAN / GTIN | 3606489832896 |
| Sales unit | pcs |
| Package quantity | 16 pcs |
| Range | TeSys |
| Product name | TeSys island |
| Device short name | TPRDG |
| Product or component type | Digital IO module |
| Device presentation | IO module providing 4 digital inputs and 2 digital outputs; Enabling advanced control functions in a TeSys island system; Control of third parties power devices when associated to a TPRPM power module; Operational only when connected to a bus coupler TPRBC |
| Function of module | Control of 4 sink/source digital inputs with common point; Control of 2 sink/source digital outputs with common point |
| Product compatibility | TPRBC bus coupler; TPRPM power module |
| Discrete input number | 4 isolated with common point conforming to IEC 61131-2 Type 1 |
| Discrete input voltage | 24 V DC (voltage limits: 19.2...28.8 V) |
| Discrete input current | 7 mA at 24 V |
| Input impedance | 3.43 kOhm |
| Discrete input logic | Positive or negative, 0...5 V (state 0), 15...28.8 V (state 1) |
| Discrete output number | 2 isolated with common point |
| Discrete output logic | Source or sink |
| Discrete output voltage | 24 V DC (voltage limit: 19.2...28.8 V) |
| Discrete output current | 0.5 A maximum |
| Protection type | 1 external fuse, 0.5 A fast fuse for each output |
| Response time | 5 ms at 24 V for digital input; 5 ms at 24 V for digital output |
| Local signalling | 1 LED (green/red) for DS (device status); 1 LED (green) for I0 (input 1 status); 1 LED (green) for I1 (input 2 status); 1 LED (green) for I2 (input 3 status); 1 LED (green) for I3 (input 4 status); 1 LED (green) for Q0 (output 1 status); 1 LED (green) for Q1 (output 2 status) |
| [Us] rated supply voltage | 24 V DC supplied by the bus coupler |
| Current consumption | 10 mA |
| Power dissipation in W | 0.5 W maximum |
| [Uimp] rated impulse withstand voltage | 0.5 kV conforming to IEC 61010-1 |
| Standards | IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201 |
| Product certifications | UL; EAC (pending); CSA |
| Mounting mode | Horizontal and vertical (35 mm symmetrical rail) |
| Connections - terminals | Input/output circuit: removable spring terminal block 8 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) rigid; Input/output circuit: removable spring terminal block 8 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Input/output circuit: removable spring terminal block 8 cable(s) 0.25…2.5 mm² (22 AWG...14 AWG) flexible with cable end |
| Width | 25 mm |
| Height | 118 mm |
| Depth | 114 mm |
| Product weight | 0.136 kg |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -10…60 °C |
| Relative humidity | 5…95 % |
| Operating altitude | 0...2000 m without derating |
| IP degree of protection | IP20 |
| Pollution degree | 2 |
| Protective treatment | TC |
| Fire resistance | 960 °C conforming to UL 94 |
| Shock resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Electromagnetic compatibility | Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4; Surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.5 cm |
| Package 1 Width | 13.5 cm |
| Package 1 Length | 15.5 cm |
| Package 1 Weight | 244.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 4.684 kg |
| Country of origin | ID |
| Warranty (in months) | 18 |
| Supporting protocol for EtherCAT | No |
| Voltage type (supply voltage) | DC |
| Number of digital inputs | 4 |
| Number of digital outputs | 2 |
| Digital inputs configurable | Yes |
| Digital outputs configurable | Yes |
| Input current at signal 1 | 7 mA |
| Type of voltage (input voltage) | DC |
| Output current | 0.5 A |
| Type of output voltage | DC |
| Short-circuit protection, outputs available | No |
| Number of HW-interfaces other | 2 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Degree of protection (IP) | IP20 |
| Type of electric connection | Plug-in connection |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |