cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Schneider Electric SIL interface module, TeSys island TPRSM001

Schneider Electric · Electrical Components · France · se.com
Part Number
TPRSM001  ·  HS 8538.90
Schneider Electric SIL interface module, TeSys island TPRSM001

Schneider Electric TPRSM001 — SIL interface module, TeSys island.

Technical Specifications

Manufacturer part number (MPN)TPRSM001
EAN / GTIN3606489832872
Sales unitpcs
Package quantity16 pcs
RangeTeSys
Product nameTeSys island
Device short nameTPRSM
Product or component typeSIL interface module
Device presentationImplementation of a safe stop function for SIL motor starters TPRSS; Safe stop operable for safety-related system conforming to ISO 13849-1; Operational only when connected to a bus coupler TPRBC
Function of moduleSafe stop with 1NC or 2NC contacts monitoring
Product compatibilityTPRBC bus coupler; TPRSS SIL motor starter
[Ue] rated operational voltageInput/output circuit: 24 V DC
[Ui] rated insulation voltageInput/output circuit: 50 V
[Uimp] rated impulse withstand voltage2 kV for input/output circuit conforming to IEC 60947-1
Overvoltage categoryIII
Input typeIsolated switching input for safe stop
Input protection typeInternal, electronic
Input voltage15...28.8 V DC state 1; 0...5 V DC state 0
Output typeRelay instantaneous opening, 1 NO circuit(s), potential free
Output thermal current8 A for relay output
Protection typeExternal fuse, 8 A gG fuse for relay output
Local signalling1 LED (green/red) for DS (device status); 1 LED (green/red) for SS (safe stop status)
[Us] rated supply voltage24 V DC supplied by the bus coupler
Current consumption10 mA
Power dissipation in W0.7 W maximum
Safety functionSafe stop: category 0 conforming to IEC 60204-1; Safe stop: category 1 conforming to IEC 60204-1
Safety integrity levelSIL 2 conforming to IEC 61508 in single channel system architecture; SILCL 2 conforming to IEC 62061 in single channel system architecture; PL = d category 2 conforming to ISO 13849-1 in single channel system architecture
StandardsUL 60947-5-1; IEC 60947-5-1
Product certificationsEAC (pending); UL; CSA
Mounting modeHorizontal and vertical (35 mm symmetrical rail)
Connections - terminalsControl circuit: removable spring terminal block 5 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) rigid; Control circuit: removable spring terminal block 5 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: removable spring terminal block 5 cable(s) 0.25…2.5 mm² (22 AWG...14 AWG) flexible with cable end
Width25 mm
Height118 mm
Depth114 mm
Product weight0.159 kg
Ambient air temperature for storage-25…70 °C
Ambient air temperature for operation-10…60 °C
Relative humidity5…95 %
Operating altitude0...2000 m without derating
IP degree of protectionIP20
Pollution degree2
Protective treatmentTC
Fire resistance960 °C conforming to UL 94
Shock resistance15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibilityElectrostatic discharge, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF fields, level 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transients immunity test, level 3, 2 kV, conforming to EN/IEC 61000-4-4; Surge immunity test (common mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width13.500 cm
Package 1 Length15.500 cm
Package 1 Weight270.000 g
Unit Type of Package 2S03
Number of Units in Package 216
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.019 kg
Country of originID
Warranty (in months)18
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Voltage type (supply voltage)DC
Number of functions1
Number of HW-interfaces other2
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
Suitable for countingNo
Suitable for weighingNo
Suitable for temperature controlNo
Suitable for welding controlNo
Suitable for pressure controlNo
Suitable for NCNo
Suitable for electronic positioningNo
Suitable for CNCNo
Suitable for SSINo
Suitable for incremental data detectionNo
Suitable for detection absolute valueNo
Suitable for flux controllerNo
Suitable for flux measurementNo
Suitable for path controllerNo
Suitable for cam controllerNo
Suitable for multi-axis controlNo
Suitable for single-axis controllerNo
Suitable for multi-axis positioningNo
Suitable for single-axis positioningNo
Function block restart blockageNo
Function block automatic resetNo
Contactor control function blockYes
Function block emergency stopNo
Function block contactless working protection installationNo
Function block affirm push buttonNo
Function block 2-hand switchingNo
Function block operating mode selectionNo
Function block access controlNo
Degree of protection (IP)IP20
Fieldbus connection over separate bus coupler possibleYes
Frequency measurementNo
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsYes
SIL according to IEC 615082
Performance level according to EN ISO 13849-1Level d
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone

Properties

MOQ1

Cross-References