Schneider Electric Direct online starter, TeSys island, 15A AC-1, 9A AC-3, 4kW / 5hp TPRST009

Schneider Electric · Electrical Components · France · se.com
Part Number
TPRST009  ·  HS 8536.50
Schneider Electric Direct online starter, TeSys island, 15A AC-1, 9A AC-3, 4kW / 5hp TPRST009

Schneider Electric TPRST009 Direct starter TeSys island 15A AC-1, 9A AC-3, 4kW / 5hk.

Technical Specifications

Manufacturer part number (MPN)TPRST009
EAN / GTIN3606489832742
Sales unitpcs
Package quantity14 pcs
Power4 kW
Rated current9 A
RangeTeSys
Product nameTeSys island
Device short nameTPRST
Product or component typeMotor starter
Motor starter typeDirect on line
Device presentationDirect starter connected to an automation controller through a bus coupler; Operational only when connected to a bus coupler
Function availableUpstream voltage presence detection; Electrical line and load protection; Power and energy monitoring when connected with TPRVM voltage module
Product compatibilityTPRBC bus coupler; TPRVM voltage interface module
Poles description3P (3 NO)
Utilisation categoryAC-1; AC-2; AC-3; AC-4; AC-3e
Motor power kW2.2 kW at 230 V 50 Hz (AC-3); 4 kW at 380...415 V 50 Hz (AC-3); 4 kW at 440 V 50 Hz (AC-3); 5.5 kW at 500 V 50 Hz (AC-3); 5.5 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)0.33 hp at 120 V AC 60 Hz for 1 phase motors; 1 hp at 240 V AC 60 Hz for 1 phase motors; 2 hp at 208 V AC 60 Hz for 3 phases motors; 2 hp at 240 V AC 60 Hz for 3 phases motors; 5 hp at 480 V AC 60 Hz for 3 phases motors; 7.5 hp at 600 V AC 60 Hz for 3 phases motors
[Ue] rated operational voltage<= 690 V AC 47...63 Hz
[Ie] rated operational current9 A (at <50 °C) at <= 440 V AC-3; 15 A (at <50 °C) at <= 440 V AC-1
[Ith] conventional free air thermal current15 A (at 50 °C)
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Overvoltage categoryIII
Thermal protection adjustment range0.18…9 A
Thermal overload classClass 5…30
ResetRemotely or automatically
Irms rated making capacity250 A at 440 V conforming to IEC 60947
Rated breaking capacity250 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current210 A 40 °C - 1 s; 105 A 40 °C - 10 s; 61 A 40 °C - 1 min; 30 A 40 °C - 10 min
Average impedance2.5 mOhm - Ith 15 A 50 Hz
Power dissipation per pole0.2 W AC-3 - Ith 9 A; 0.56 W AC-1 - Ith 15 A
[Uc] control circuit voltage24 V DC supplied by the bus coupler
Current consumption160 mA contactor sealed; 160 mA contactor closing
Power dissipation in W3.5 W at Ie AC-3
Mechanical durability30 Mcycles
Electrical durability2 Mcycles 9 A AC-3 at Ue 440 V; 1.2 Mcycles 15 A AC-1 at Ue 440 V
Maximum operating rate3600 cyc/mn AC-3
Operating time< 100 ms closing; < 30 ms opening
Safety performance levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection typeThermal overload protection; Motor overheat; Overcurrent; Undercurrent; Jam; Long start; Stall; Rapid cycle lockout; Phase sequence; Rapid restart lockout; Phase reversal; Phase loss; Phase unbalance; Ground current
Monitoring typeTime device ON; Time device switch ON; Number of faults; Number of switching cycles; Number of device power cycles; Average current Iavg; Average voltage Vavg; Max current Imax; Max voltage Vmax; Active and reactive power with voltage module; Active and reactive energy with voltage module; True power factor with voltage module
Local signalling1 LED (green/red) for DS (device status); 1 LED (green/red) for LS (load status)
StandardsEN/IEC 60947-1; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1
Product certificationsEAC; CSA; CCC; UL
Mounting modeHorizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminalsScrew-clamp terminals 1 cable(s) 1…4 mm² (16 AWG...12 AWG) rigid; Screw-clamp terminals 2 cable(s) 1…4 mm² (16 AWG...12 AWG) rigid; Screw-clamp terminals 1 cable(s) 1.5…4 mm² (16 AWG...12 AWG) flexible without cable end; Screw-clamp terminals 2 cable(s) 1.5…4 mm² (16 AWG...12 AWG) flexible without cable end; Screw-clamp terminals 1 cable(s) 1…4 mm² (16 AWG...12 AWG) flexible with cable end; Screw-clamp terminals 2 cable(s) 1…2.5 mm² (16 AWG...14 AWG) flexible with cable end
Tightening torque1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2
Width45 mm
Height116 mm
Depth115 mm
Product weight0.656 kg
Ambient air temperature for storage-25…70 °C
Ambient air temperature for operation-10…50 °C without derating; 50…60 °C with current derating
Relative humidity5…95 %
Operating altitude0...2000 m without derating
IP degree of protectionIP20
Pollution degree2
Protective treatmentTC
Fire resistance960 °C conforming to UL 94; 850 °C conforming to IEC 60695-2-1; 650 °C conforming to IEC 60695-2-12
Shock resistance15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibilityElectrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4; Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5; Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5; Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Country of originFR
Warranty (in months)18
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC20.4–28.8 V
Voltage type (supply voltage)DC
Number of inputs1
Permitted voltage at input0–690 V
Type of voltage (input voltage)AC
Type of digital outputNone
Permitted voltage at output0–690 V
Type of output voltageAC
Short-circuit protection, outputs availableNo
Number of motor outlets1
Rated operation current of the motor0.18–9 A
With motor current parameter settingNo
Type of electrical connection at the motor outputScrew connection
With brake outputNo
With thermal motor protectionYes
Number of HW-interfaces other2
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
Degree of protection (IP)IP20
Type of electric connectionPlug-in connection
Fieldbus connection over separate bus coupler possibleYes
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone

Properties

MOQ1

Cross-References