Regeneringsmodul 7,5kW ATV320,340,900 (ATVRU75N4)

Schneider Electric · Drives & Controllers · Drive Accessories · France · se.com
Part Number
ATVRU75N4  ·  HS 8537.10
Regeneringsmodul 7,5kW ATV320,340,900 (ATVRU75N4)

Schneider Electric ATVRU75N4 — Altivar variable-frequency drive. IGBT variable-frequency drive for AC motor speed control. Regenereringsmodul 7.5kW for ATV320 / 340/900 can sette energy tilbake on the mains 3 pcs can is connected parallelt.

Technical Specifications

Manufacturer part number (MPN)ATVRU75N4
EAN / GTIN3606481144218
Sales unitpcs
Package quantity6 pcs
Power7.5 kW
Range of productAltivar
Range compatibilityAltivar Machine ATV340; Altivar Process ATV900; Altivar Machine ATV320
Product or component typePower module
Device applicationEnergy regeneration
[Us] rated supply voltage380...500 V - 15...10 %
[Ue] rated operational voltage456...778 V DC
Rated power in W6.8 kW
Network frequency45...65 Hz
Network number of phases3 phases
fixing modeBy screws
Maximum voltage drop at rated load3 %
Electrical connectionControl: removable screw terminal block: 0.5...1.5 mm², 20 AWG...16 AWG (bottom); Power supply: removable screw terminal block: 2.5...4 mm², 12 AWG...10 AWG (top); DC bus: removable screw terminal block: 2.5...4 mm², 12 AWG...10 AWG (bottom)
Input current16.5 A at 380 V AC for voltage inputs (continuous); 14.5 A at 500 V AC for voltage inputs (continuous); 22.9 A at 380 V AC for voltage inputs (transient for 60 s); 19.1 A at 500 V AC for voltage inputs (transient for 60 s)
Input power6.8 kW at 380...500 V AC for voltage inputs (continuous); 10.2 kW at 380...500 V AC for voltage inputs (transient for 60 s)
Maximum DC bus voltage300...880 V DC
Output current13.4 A at 380 V AC (continuous); 11.9 A at 500 V AC (continuous); 18.4 A at 380 V AC (transient for 60 s); 15.4 A at 500 V AC (transient for 60 s)
Width80 mm
Height337 mm
Depth175 mm
Product weight6 kg
StandardsIEC 61800-5-1; IEC 61800-3
Product certificationscUL
Ambient air temperature for operation-10…50 °C without derating; 50…60 °C with derating factor
Ambient air temperature for storage-40…70 °C
Operating altitude<= 1000 m without derating; 1000...3000 m with power derating 1 % per 100 m
Operating positionVertical or horizontal position
Type of coolingFan
Environmental characteristicChemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S2 conforming to IEC 60721-3-3
Pollution degree2 conforming to IEC 61800-5-1
Number of Units in Package 11
Number of Units in Package 26
Country of originID
Warranty (in months)18
AccessoryYes
Spare partNo