cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-06
sales@cballast.com
cballast.com

Schneider Altivar 12 ATV12 1.5kW 1PH 200-240V Drive

Schneider Electric · Drives & Motors · Variable Frequency Drives · France · se.com
Part Number
ATV12HU15M2  ·  HS 8504.40
Schneider Altivar 12 ATV12 1.5kW 1PH 200-240V Drive

Schneider Electric ATV12HU15M2 — Altivar variable-frequency drive. IGBT variable-frequency drive for AC motor speed control. Altivar 12 variable speed drive, 1.5kW (2HP), single-phase 200-240V input, three-phase motor output. Integrated EMC filter, Modbus RTU.

Technical Specifications

SeriesAltivar 12 (ATV12)
Rated Power1.5kW (2HP)
Supply Voltage1-phase 200-240V AC, 50/60Hz
Output Voltage3-phase, equal to supply
Control TypeV/f and sensorless flux vector
CommunicationModbus RTU integrated
Emc FilterClass B integrated
Ip RatingIP20
MountingWall or DIN rail (with kit)
Power1.5 kW
Range of productAltivar 12
Product or component typeVariable speed drive
Product specific applicationSimple machine
mounting modeCabinet mount
Communication port protocolModbus
Supply frequency50/60 Hz +/- 5 %
[Us] rated supply voltage200...240 V - 15...10 %
nominal output current7.5 A
Motor power kW1.5 kW
Motor power hp2 hp
EMC filterIntegrated
IP degree of protectionIP20
Discrete input number4
Discrete output number2
Analogue input number1
Analogue output number1
Relay output number1
Physical interface2-wire RS 485
Connector type1 RJ45
Continuous output current7.5 A at 4 kHz
Method of accessServer Modbus serial
Speed drive output frequency0.5…400 Hz
Speed range1…20
Sampling duration20 ms, tolerance +/- 1 ms for logic input; 10 ms for analogue input
Linearity error+/- 0.3 % of maximum value for analogue input
Frequency resolutionAnalog input: converter A/D, 10 bits; Display unit: 0.1 Hz
Time constant20 ms +/- 1 ms for reference change
Transmission rate9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s
Transmission frameRTU
Number of addresses1…247
Data format8 bits, configurable odd, even or no parity
Communication serviceRead holding registers (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43)
Type of polarizationNo impedance
4 quadrant operation possibleFalse
Asynchronous motor control profileSensorless flux vector control; Quadratic voltage/frequency ratio; Voltage/frequency ratio (V/f)
Maximum output frequency4 kHz
Transient overtorque150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration rampsU; S; Linear from 0 to 999.9 s
Motor slip compensationAdjustable; Preset in factory
Switching frequency2...16 kHz adjustable; 4...16 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Line current17.8 A at 100 V (heavy duty); 14.9 A at 120 V (heavy duty)
Maximum input current14.9 A
Maximum output voltage240 V
Apparent power3.6 kVA at 240 V (heavy duty)
Maximum transient current11.2 A during 60 s (heavy duty); 12.4 A during 2 s (heavy duty)
Network frequency50...60 Hz
Relative symmetric network frequency tolerance5 %
Prospective line Isc1 kA
Base load current at high overload7.5 A
Power dissipation in WForced cooling: 72.0 W
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)False
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeLine supply overvoltage; Line supply undervoltage; Overcurrent between output phases and earth; Overheating protection; Short-circuit between motor phases; Against input phase loss in three-phase; Thermal motor protection via the drive by continuous calculation of I²t
Tightening torque1.2 N.m
InsulationElectrical between power and control
Quantity per setSet of 1
Width105 mm
Height142 mm
Depth156.2 mm
Product weight1.4 kg
Operating altitude> 1000...2000 m with current derating 1 % per 100 m; <= 1000 m without derating
Operating positionVertical +/- 10 degree
Product certificationsNOM; CSA; C-Tick; UL; GOST; RCM; KC
MarkingCE
StandardsUL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3
Assembly styleWith heat sink
Electromagnetic compatibilityElectrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Surge immunity test level 3 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Volume of cooling air16 m3/h
Overvoltage categoryClass III
Regulation loopAdjustable PID regulator
Electromagnetic emissionRadiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable; Conducted emissions with integrated EMC filter environment 1 category C1 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m; Conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m; Conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m; Conducted emissions with additional EMC filter environment 2 category C3 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m; Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 4...16 kHz shielded motor cable <5 m; Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m
Vibration resistance1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6
Shock resistance15 gn conforming to IEC 60068-2-27 for 11 ms
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3
Noise level45 dB
Pollution degree2
Ambient air transport temperature-25…70 °C
Ambient air temperature for operation-10…50 °C without derating; 50…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage-25…70 °C
Number of Units in Package 11
Number of Units in Package 230
Country of originID
Warranty (in months)18
EAN3606480071096

Properties

Primary standardIEC 61800-5-1; IEC 61800-3
MOQ1

Compatibility

SoMove software via Modbus. Compatible with VW3A1006 remote display and VW3A1101 graphic terminal.

Standards

Approvals

Attached Documents