CPU, 24DC 18/12 In/O PNP, 3 EXP (CP1LM30DT1D)

Omron · Control & Automation · PLCs
Part Number
CP1LM30DT1D  ·  HS 8471.41
CPU, 24DC 18/12 In/O PNP, 3 EXP (CP1LM30DT1D)

Omron CP1LM30DT1D CP1L PLS CPU, 24VDC supply, 18x 24VDC input, 12x PNP output 0.3A, 10Ksteg program, 32Kord data minne.

Technical Specifications

Manufacturer part number (MPN)CP1LM30DT1D
EAN / GTIN4547648359788
Sales unitpcs
Output typePNP
Width130 mm
ModelCompact
Height90 mm
Depth85 mm
With displayNo
Suitable for safety functionsNo
Number of digital inputs18
Number of digital outputs12
Number of analogue inputs1
Voltage type (supply voltage)DC
Type of memoryFLASH
Memory size144 kByte
Processing time (1K, binary operation)0.55 ms
Supporting protocol for LONNo
Number of HW-interfaces USB1
Number of HW-interfaces other1
With optical interfaceNo
Additional program memory possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
RedundancyNo
Suitable for rail mountingYes
Explosion safety category for gasNone
Explosion safety category for dustNone
System accessoryNo
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
IO link masterNo
Max. number of time switches4096
Performance level according to EN ISO 13849-1Level a
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage DC20.4–26.4 V
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
SIL according to IEC 61508None
Country of originNetherlands

Properties

MOQ1

Cross-References

Attached Documents