PLS 24INN/16UT 230VAC (CP1H-X40DR-A)

Omron · Control & Automation · PLCs
Part Number
CP1H-X40DR-A  ·  HS 8536.90
PLS 24INN/16UT 230VAC (CP1H-X40DR-A)

Omron CP1H-X40DR-A PLS, 20K steg program, 32K ord data minne, 100-240VAC supply, 24x 24VDC input, 16x relay output 2A, USB programmeringsport.

Technical Specifications

Manufacturer part number (MPN)CP1H-X40DR-A
EAN / GTIN4547648203579
HS code8536.90
Sales unitpcs
Voltage230 V AC
Width150 mm
ModelCompact
Height90 mm
Depth85 mm
With displayNo
Suitable for safety functionsNo
Number of digital inputs24
Number of digital outputs16
Voltage type (supply voltage)AC
Type of memoryFLASH
Memory size184 kByte
Processing time (1K, binary operation)0.1 ms
Max. number of addressable analogue I/O-ports16
Max. number of addressable digital I/O-ports320
Supporting protocol for LONNo
Number of HW-interfaces USB1
Number of HW-interfaces other1
With optical interfaceNo
Additional program memory possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
RedundancyNo
Suitable for rail mountingYes
Explosion safety category for gasNone
Explosion safety category for dustNone
System accessoryNo
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
IO link masterNo
Number of relay outputs16
Max. number of time switches4090
Performance level according to EN ISO 13849-1Level a
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage AC 50 Hz85–264 V
Supply voltage AC 60 Hz85–264 V
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
SIL according to IEC 61508None
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Country of originChina