| Manufacturer part number (MPN) | CF8821-01-03 |
| Brand | IGUS |
| Category | Tools |
| Number of cores and conductor nominal cross-section | (3x0.14)C |
| Copper index kg/km | 13 kg/km |
| Stranding type | Stranded in layers |
| Shipping weight (kg or kg/m) | 0.035 |
| Outer diameter (d) max. mm | 5.5 mm |
| Weight per km | 35 kg/km |
| Min. bend radius, e-chain (factor) | 12.5 x d |
| Min. bend radius, e-chain | 68.75 mm |
| Min. bend radius, flexible (factor) | 10 x d |
| Min. bend radius, flexible | 55 mm |
| Min. bend radius, fixed (factor) | 7 x d |
| Min. bend radius, fixed | 38.5 mm |
| Temperature e-chain® | +5°C up to +70°C |
| Temperature, flexible | -5°C to +70°C (according to DIN EN 60811-504) |
| Temperature, fixed | -15°C to +70°C (according to DIN EN 50305) |
| v max. unsupported (speed) | 3 m/s |
| a max. (acceleration) | 20 m/s² |
| travel length | Unsupported up to 10 m |
| torsion | No Torsion |
| Conductor | Conductor consisting of bare copper wires (according to DIN EN 60228). |
| Core insulation | Mechanically high-quality TPE mixture. |
| Core stranding | Cores wound with an optimised pitch length. |
| Overall shield | Braiding made of tinned copper wires. Cover approx. 60% optical. |
| Outer jacket | Low-adhesion PVC mixture, adapted to suit the requirements in e-chains®. |
| Outer jacket colour | Jet black (comparable to RAL 9005) |
| Nominal voltage | 300/300V (according to DIN VDE 0298-3) |
| Test voltage | 1500V (according to DIN EN 50395) |
| Silicone-free | Free from silicone which can affect paint adhesion (according to PV 3.10.7 – status 1992) |
| EAC | Certificate No. RU C-DE.ME77.B.00300/19 |
| REACH | In accordance with Regulation (EC) No. 1907/2006 (REACH) |
| CE | According to 2014/35/EU |
| UL/CSA AWM | Style 10493 and 2464, 300 V, 80 °C |
| UL verified | Certificate no |
| V293650 | "The igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year“ |
| Flame-retardant | According to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame |
| NFPA | According to NFPA 79-2018, chapter 12.9 |