chainflex® control cable CF2 (CF2.01.04)

igus · Safety & Detection · Tools · Germany · igus.com
Part Number
CF2.01.04  ·  HS 8544.49
chainflex® control cable CF2 (CF2.01.04)

chainflex® control cable CF2

Technical Specifications

Manufacturer part number (MPN)CF2.01.04
BrandIGUS
CategoryTools
Number of cores and conductor nominal cross-section(4x0.14)C
Copper index kg/km18 kg/km
Shipping weight (kg or kg/m)0.049
Outer diameter (d) max. mm6.5 mm
Weight per km49 kg/km
Min. bend radius, e-chain (factor)5 x d
Min. bend radius, e-chain32.5 mm
Min. bend radius, flexible (factor)4 x d
Min. bend radius, flexible26 mm
Min. bend radius, fixed (factor)3 x d
Min. bend radius, fixed19.5 mm
Temperature e-chain®-20°C up to +80°C
Temperature, flexible-40°C to +80°C (according to DIN EN 60811-504)
Temperature, fixed-50°C to +80°C (according to DIN EN 50305)
v max. unsupported (speed)10 m/s
v max. gliding (speed)5 m/s
a max. (acceleration)80 m/s²
travel lengthUnsupported travel distances and up to 100 m for gliding applications
torsionNo Torsion
ConductorStranded conductor in an especially bend-resistant version consisting of bare copper wires (according to DIN EN 60228).
Core insulationMechanically high-quality TPE mixture.
Core strandingCores wound in a layer with short pitch length.
Inner jacketPVC mixture adapted to suit the requirements in e-chains®.
Overall shieldExtremely flexible braiding made of tinned copper wires. Coverage linear approx. 70%, optical approx. 90%
Outer jacketLow-adhesion mixture on the basis of PUR, highly abrasion and bend-resistant, adapted to suit the requirements in hanging applications (according to DIN EN 50363-10-2).
Outer jacket colourAnthracite grey (comparable to RAL 7016)
Nominal voltage300/500V (according to DIN VDE 0298-3)
Test voltage2000V (according to DIN EN 50395)
UV resistanceHigh
Oil resistanceOil-resistant (according to DIN EN 50363-10-2), Class 3
Silicone-freeFree from silicone which can affect paint adhesion (according to PV 3.10.7 – status 1992)
EACCertificate No. RU C-DE.ME77.B.00300/19
REACHIn accordance with Regulation (EC) No. 1907/2006 (REACH)
Lead-freeAccording to 2011/65/EU (RoHs-II/RoHS-III)
CleanroomAccording to ISO Class 1 The outer jacket material of this series complies with CF77.UL.05.12.D - tested by IPA according to standard DIN EN ISO 14644-1
CEAccording to 2014/35/EU
UL/CSA AWMStyle 10493 and 20317, 300 V, 80 °C
UL verifiedCertificate no
V293650"The igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year“
Flame-retardantAccording to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame
NFPAAccording to NFPA 79-2018, chapter 12.9
OffshoreMUD-resistant according to NEK 606 - status 2018

Properties

MOQ1

Cross-References