| Manufacturer part number (MPN) | 5337412 |
| Brand | Fluke |
| Category | Tools |
| DC Voltage Range | 0.1 mV to 1000 V |
| DC Voltage Accuracy | ±(0.05% + 1) |
| DC Voltage Maximum resolution | 0.1 mV |
| AC Voltage Range | 0.1 mV to 1000 V |
| AC Voltage Accuracy | ±(0.7% + 4) true-rms |
| AC Voltage AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| AC Voltage Maximum resolution | 0.1 mV |
| DC Current Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| DC Current Amps accuracy | ±(0.2% + 2) |
| DC Current Maximum resolution | 0.1 µA |
| AC Current Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
| AC Current Amps accuracy | ±(1.0% + 2) true-rms |
| AC Current Maximum resolution | 0.1 µA |
| Resistance Range | 0.1 Ω to 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Resistance Maximum resolution | 0.1 Ω |
| Capacitance Range | 0.01 nF to 9999 μF |
| Capacitance Accuracy | ±(1% + 2) |
| Capacitance Maximum resolution | 0.01 nF |
| Frequency Range | 0.5 Hz to 199.99 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Frequency Maximum resolution | 0.01 Hz |
| Duty cycle Maximum duty cycle | 99.9% |
| Duty cycle Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle Maximum resolution | 0.1% |
| Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
| 80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
| Conductance Maximum conductance | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Conductance Maximum resolution | 0.01 nS |
| Diode test Range | 2 V |
| Diode test Resolution | 0.001V |
| Diode test Accuracy | ±(1% + 1) |
| Diagnostics and data storage Peak Min/Max | 250 μS |
| Diagnostics and data storage Min/Max/Avg | Yes |
| Diagnostics and data storage Reading hold/Auto (Touch) Hold | Yes |
| Diagnostics and data storage Relative reference | Yes |
| Display Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
| Display Analog bar graph | 32 segments, updates 40/second |
| Display Backlight | Two level |
| Low pass filter (VFD measurements) | Yes |
| Input Alert™ | Yes |
| Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
| Agency approvals | CE, CSA |
| IP rating | IEC 60529: IP67 |
| Power | Three AA batteries. 800 hours typical, without backlight |
| Size | 6.0 x 10.1 x 21.5 cm (with holster) |
| Weight | 698.5 g (with holster) |
| Warranty | Limited lifetime |
| Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C |
| Storage temperature | -40 °C to + 60 °C |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
| Operating altitude | 2000 m |
| PVLEAD1 | PVLEAD3 |
| Length 60” | 36”, 12” |