| Manufacturer part number (MPN) | 5602278 |
| Brand | Fluke |
| Category | Tools |
| PVA-1500T2 | PVA-1500HE2 |
| Voltage Range (Voc) | 20 to 1500V DC |
| Module Efficiency <19% | 0 to 30A DC |
| Module Efficiency ≥19% 0 to 10A DC | 0 to 30A DC |
| Voltage Accuracy (0 °C to 45 °C) | ±(0.5% ±0.25V) |
| Current Accuracy (0 °C to 45 °C) | ±(0.5% ±0.04A) |
| Power Accuracy (0 °C to 45 °C) | ±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %) |
| Voltage Resolution | 25 mV |
| Current Resolution | 2 mA |
| Sweep-to-sweep delay (@VOC ≤ 1350V) | <9 seconds |
| Max number of I-V sweeps per hour (@VOC ≤ 1350V) | 400 sweeps/hr |
| Max megawatts measured per hour | 3.5 MW/hr |
| # sweeps at 18 s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 550 (45 °C, 113 °F ambient) |
| # sweeps at 9s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 330 (45 °C, 113 °F ambient) |
| I-V Trace Points | 100 or 500 (selectable) |
| I-V Sweep Duration | 0.05 to 2 seconds (typically 0.2 seconds for PV strings) |
| Operating Temperature Range | 0 °C to 45 °C, 32 °F to 113 °F |
| Storage Temperature Range | -20 °C to 65 °C, -4 °F to 149 °F |
| Operating Humidity | <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used. |
| Altitude | 2000 m max |
| Battery Charging Time | 6 hr |
| Battery Run Time Approx. 8 hr | Approx. 7 hr |
| Safety and Regulatory | CAT III 1500V IEC 61010-1: Pollution Degree 2 |
| Warning Features | Over-voltage, over-current, over-temperature, reverse polarity |
| PV Connector Staubli MC4-EVO2 | Banana Jacks |
| Charging/Charged LED | Yes |
| In-the-field firmware update-ready | Yes |
| Interface to Tablet/Laptop | Wi-Fi interface between user tablet or laptop, I-V unit and SolSensor™ |
| Weight 6.6 kg, 14.55 lb | 7.3 kg, 16.09 lb |
| 43.2 cm, 1.41 ft (including test lead and strain reliefs) | 53.3 cm, 1.74 ft |
| Width | 21.6 cm, 8.50 in |
| Depth | 15.2 cm, 5.98 in |
| Voltage Range | 0 to 1500V DC |
| Current Range | 0 to 30A DC |
| Temperature | 0 °C to 45 °C, 32 °F to 113 °F |
| Humidity | Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) |
| Pollution Degree | 2 |
| Lead Length | 152 cm, 59.84 in |
| Lead Colors | Positive=red, negative=black |
| Manufacturer (Test Leads and Alligator Clips) | Staubli |
| Sensor Type | Silicon photodiode with corrections for temperature, spectral, and angular effects |
| Measurement Range | 100 W/m² to 1500 W/m² |
| Accuracy | ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m² |
| Resolution | 1 W/m² |
| Measurement Interval | Typically, 3.5 s |
| Measurement Cynchronization with I-V Curve | Typically, <1 s |
| Wireless Range (open line of sight) | 100 m, 328 ft |
| Battery Run Time | >16 hr typical use |
| 600.0 mV Resolution | 0.1 mV |
| 600.0 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 600.0 mV Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3) |
| 6.000 V Resolution | 0.001 V |
| 6.000 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(1% + 3) |
| 6.000 V Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3) |
| 1000 V Resolution | 1 V |
| 1000 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) | ±(2% + 3) |
| 1000 V Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) | ±(2% + 3)¹ |
| 600.0 mV Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 6.000 V Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| 1000 V Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) | +(2% + 3), -(6% - 3) |
| Range Resolution | Accuracy ±(% of Rdg + Counts) |
| 6.000 V dc 0.001 V | ±(0.09% + 2) |
| 60.00 V dc 0.01 V | ±(0.09% + 2) |
| 600.0 V dc 0.1 V | ±(0.09% + 2) |
| 1000 V dc 1 V | ±(0.09% + 2) |
| Input impedance | 10 MΩ (nominal), <100 pF |
| Normal mode rejection ratio | >60 dB @ 50 Hz or 60 Hz |
| Common mode rejection ratio | >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) |
| 600.0 mVdc 0.1 mV | ±(0.1% + 1) |
| Range | 400 mA |
| Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)¹ |
| Burden voltage (Typical) | 2 mV/mA |
| Overload | 600 mA for 2 minutes maximum |
| Fuse protection for mA input | 0.44 mA, 1000 V, IR 10 kA |
| AC conversion | Inputs are ac-coupled and calibrated to the rms value of its wave input |
| 600.0 Ω 0.1 Ω | ±(0.9% + 2) |
| 6.000 kΩ 0.001 kΩ | ±(0.9% + 2) |
| 60.00 kΩ 0.01 kΩ | ±(0.9% + 2) |
| 600.0 kΩ 0.1 KΩ | ±(0.9% + 2) |
| 6.000 MΩ 0.001 MΩ | ±(0.9% + 2) |
| 50.0 MΩ ² 0.01 MΩ | ±(1.5% + 3) |
| Overload protection | 1000 V rms or dc |
| Open circuit test voltage | <8.0 V dc |
| Short circuit current | <1.1 mA |
| Diode test indication | Display voltage drop: 0.6 V at1.0 mA nominal test current: |
| Continuity indication | Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω |
| Open circuit voltage | <8.0 V |
| Response time | >1 m sec |
| 99.99 Hz 0.01 Hz | ±(0.1% + 1) |
| 999.9 Hz 0.1 Hz | ±(0.1% + 1) |
| 9.999 kHz 0.001 kHz | ±(0.1% + 1) |
| 99.99 kHz 0.01 kHz | ±(0.1% + 1) |
| 600.0 mV ac V ac Sensitivity (RMS Its Wave)¹ 5 Hz to 20 kHz | 100.0 mV |
| V ac Sensitivity (RMS Its Wave)¹ 20 kHz to 100 kHz | 150.0 mV |
| 6.0 V V ac Sensitivity (RMS Its Wave)¹ 5 Hz to 20 kHz | 1.0 V |
| 6.0 V V ac Sensitivity (RMS Its Wave)¹ 20 kHz to 100 kHz | 1.5 V |
| 6.0 V DC Trigger Levels¹ to 20 kHz² | -400.0 mV and 2.5 V |
| 60.0 V V ac Sensitivity (RMS Its Wave)¹ 5 Hz to 20 kHz | 10.0 V |
| 60.0 V V ac Sensitivity (RMS Its Wave)¹ 20 kHz to 100 kHz | 36.0 V |
| 60.0 V DC Trigger Levels¹ to 20 kHz² | 1.2 V and 4.0 V |
| 600.0 V V ac Sensitivity (RMS Its Wave)¹ 5 Hz to 20 kHz | 100.0 V |
| 600.0 V DC Trigger Levels¹ to 20 kHz² | 12.0 V and 40.0 V |
| 1000.0 V V ac Sensitivity (RMS Its Wave)¹ 5 Hz to 20 kHz | 300.0 V |
| 1000.0 V DC Trigger Levels¹ to 20 kHz² | 12.0 V and 40.0 V |
| 1000 nF 1 nF | ±(1.2% + 2) |
| 10.00 μF 0.01 μF | ±(1.2% + 2) |
| 100.0 μF 0.1 μF | ±(1.2% ±90 counts) |
| 9999 μF 1 μF | ±(1.2% ±90 counts) |
| -40 ° C to 537 ° C 0.1 °C | ±(1% + 10 counts) |
| -40 ° F to 998 ° F 0.1 °F | ±(1% + 18 counts) |
| Test voltages | 50, 100, 250, 500, 1000 V |
| Test voltage accuracy | +20%, -0% |
| Short-circuit test current | 1 mA nominal |
| Auto discharge | Discharge time <0.5 second for C = 1 μF or less |
| Live circuit detection | Inhibit test if terminal voltage > 30 V prior to initialization of test |
| Maximum capacitive load | Operable with up to 1 μF load |
| 50 V (0% to +20%) Display range | 0.01 to 6.00 MΩ |
| 50 V (0% to +20%) Resolution | 0.01 MΩ |
| 50 V (0% to +20%) Test current | 1 mA @ 50 kΩ |
| 50 V (0% to +20%) Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) |
| 100 V (0% to +20%) Display range | 0.01 to 6.00 MΩ |
| 100 V (0% to +20%) Resolution | 0.01 MΩ |
| 100 V (0% to +20%) Test current | 1 mA @ 100 kΩ |
| 100 V (0% to +20%) Resistance accuracy ±(% of Rdg + Counts) | ±(3% + 5 counts) |
| 250 V (0% to +20%) Display range | 0.1 to 60.0 MΩ |
| 250 V (0% to +20%) Resolution | 0.1 MΩ |
| 250 V (0% to +20%) Test current | 1 mA @ 250 kΩ |
| 250 V (0% to +20%) Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) |
| 500 V (0% to +20%) Display range | 0.1 to 60.0 MΩ |
| 500 V (0% to +20%) Resolution | 0.1 MΩ |
| 500 V (0% to +20%) Test current | 1 mA @ 500 kΩ |
| 500 V (0% to +20%) Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) |
| 1000 V (0% to +20%) Display range | 0.1 to 60.0 MΩ |
| 1000 V (0% to +20%) Resolution | 0.1 MΩ |
| 1000 V (0% to +20%) Test current | 1 mA @ 1 MΩ |
| 1000 V (0% to +20%) Resistance accuracy ±(% of Rdg + Counts) | ±(1.5% + 5 counts) |
| Maximum voltage applied to any terminal and common | 1000 V |
| Storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
| Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) |
| Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures 28 °C (82 °F) |
| Relative humidity | Noncondensing |
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
| Radio frequency communication | 2.4 GHz ISM Band |
| Radio frequency certification | FCC: T68-FBLE |
| IC | 6627A-FBLE |
| International | IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Enclosure protection | IEC 60529: IP40 (non-operating) |
| IEC 61010-1 | Pollution Degree 2 |
| IEC 61010-2-033 | CAT IV 600 V / CAT III 1000 V |
| Batteries | Four AA batteries (IEC LR6) |
| Battery life | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) |
| Weight | 550 g (1.2 lb) |
| Altitude Operating | 2000 m |
| Altitude Storage | 12,000 m |
| Over-range capability | 110% of range except for capacitance which is 100% |
| Frequency overload protection | <107 V Hz |
| Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
| Distance from Optimum i2500-10 Flex | i2500-18 Flex |
| A 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| B 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| C 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Voltage DC Maximum voltage | 1000 V |
| Voltage DC Accuracy | ±(0.05% + 1) |
| Voltage DC Maximum resolution | 10 µV |
| Voltage AC Maximum voltage | 1000 V |
| Voltage AC Accuracy | ±(0.7% + 2) True RMS |
| Voltage AC AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| Voltage AC Maximum resolution | 0.1 mV |
| Current DC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current DC Amps accuracy | ±(0.2% + 2) |
| Current DC Maximum resolution | 0.01 µA |
| Current AC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current AC Amps accuracy | ±(1.0% + 2) True RMS |
| Current AC Maximum resolution | 0.1 µA |
| Resistance Maximum resistance | 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Resistance Maximum resolution | 0.1 Ω |
| Capacitance Maximum capacitance | 9,999 µF |
| Capacitance accuracy | ±(1% + 2) |
| Capacitance Maximum resolution | 0.01 nF |
| Frequency Maximum frequency | 200 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Frequency Maximum resolution | 0.01 Hz |
| Duty cycle Maximum duty cycle | 99.9% |
| Duty cycle Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle Maximum resolution | 0.1% |
| Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
| 80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
| Conductance Maximum conductance | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Conductance Maximum resolution | 0.01 nS |
| Diode Range | 3 V |
| Diode Resolution | 1 mV |
| Diode Accuracy | ±(2% + 1) |
| Duty cycle range Accuracy | Within ±(0.2% per kHz + 0.1%) |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
| Operating Altitude | 2000 m |
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
| Agency approvals | CE, CSA, RCM |
| Size | 201 x 98 x 52 mm (with holster) |
| Display Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
| Display Analog | 32 segments, updates 40/sec |
| Display Frequency | 19,999 counts, updates 3/sec at > 10 Hz |
| Warranty | Lifetime |
| Battery Life Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 |