| Manufacturer part number (MPN) | 5602269 |
| Brand | Fluke |
| Category | Tools |
| # sweeps at 18 s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 550 (45 °C, 113 °F ambient) |
| # sweeps at 9s sweep-to-sweep delay | unlimited (25 °C, 77 °F ambient) 330 (45 °C, 113 °F ambient) |
| I-V Trace Points | 100 or 500 (selectable) |
| I-V Sweep Duration | 0.05 to 2 seconds (typically 0.2 seconds for PV strings) |
| Operating Temperature Range | 0 °C to 45 °C, 32 °F to 113 °F |
| Storage Temperature Range | -20 °C to 65 °C, -4 °F to 149 °F |
| Operating Humidity | <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used. |
| Altitude | 2000 m max |
| Battery Charging Time | 6 hr |
| Battery Run Time Approx. 8 hr | Approx. 7 hr |
| Safety and Regulatory | CAT III 1500V IEC 61010-1: Pollution Degree 2 |
| Warning Features | Over-voltage, over-current, over-temperature, reverse polarity |
| PV Connector Staubli MC4-EVO2 | Banana Jacks |
| Charging/Charged LED | Yes |
| In-the-field firmware update-ready | Yes |
| Interface to Tablet/Laptop | Wi-Fi interface between user tablet or laptop, I-V unit and SolSensor™ |
| Weight 6.6 kg, 14.55 lb | 7.3 kg, 16.09 lb |
| 43.2 cm, 1.41 ft (including test lead and strain reliefs) | 53.3 cm, 1.74 ft |
| Width | 21.6 cm, 8.50 in |
| Depth | 15.2 cm, 5.98 in |
| Voltage Range | 0 to 1500V DC |
| Current Range | 0 to 30A DC |
| Temperature | 0 °C to 45 °C, 32 °F to 113 °F |
| Humidity | Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) |
| Pollution Degree | 2 |
| Lead Length | 152 cm, 59.84 in |
| Lead Colors | Positive=red, negative=black |
| Manufacturer (Test Leads and Alligator Clips) | Staubli |
| Sensor Type | Silicon photodiode with corrections for temperature, spectral, and angular effects |
| Measurement Range | 100 W/m² to 1500 W/m² |
| Accuracy | ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m² |
| Resolution | 1 W/m² |
| Measurement Interval | Typically, 3.5 s |
| Measurement Cynchronization with I-V Curve | Typically, <1 s |
| Wireless Range (open line of sight) | 100 m, 328 ft |
| Battery Run Time | >16 hr typical use |
| Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
| Distance from Optimum i2500-10 Flex | i2500-18 Flex |
| A 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| B 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| C 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| International | IEC 61326-1: Portable, Electromagnetic Environment |
| IEC 61326-2-2 CISPR 11 | Group 1, Class A |
| Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Voltage DC Maximum voltage | 1000 V |
| Voltage DC Accuracy | ±(0.05% + 1) |
| Voltage DC Maximum resolution | 10 µV |
| Voltage AC Maximum voltage | 1000 V |
| Voltage AC Accuracy | ±(0.7% + 2) True RMS |
| Voltage AC AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| Voltage AC Maximum resolution | 0.1 mV |
| Current DC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current DC Amps accuracy | ±(0.2% + 2) |
| Current DC Maximum resolution | 0.01 µA |
| Current AC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current AC Amps accuracy | ±(1.0% + 2) True RMS |
| Current AC Maximum resolution | 0.1 µA |
| Resistance Maximum resistance | 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Resistance Maximum resolution | 0.1 Ω |
| Capacitance Maximum capacitance | 9,999 µF |
| Capacitance accuracy | ±(1% + 2) |
| Capacitance Maximum resolution | 0.01 nF |
| Frequency Maximum frequency | 200 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Frequency Maximum resolution | 0.01 Hz |
| Duty cycle Maximum duty cycle | 99.9% |
| Duty cycle Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle Maximum resolution | 0.1% |
| Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
| 80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
| Conductance Maximum conductance | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Conductance Maximum resolution | 0.01 nS |
| Diode Range | 3 V |
| Diode Resolution | 1 mV |
| Diode Accuracy | ±(2% + 1) |
| Duty cycle range Accuracy | Within ±(0.2% per kHz + 0.1%) |
| Operating temperature | –20 °C to + 55 °C |
| Storage temperature | –40 °C to + 60 °C |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
| Operating Altitude | 2000 m |
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
| Agency approvals | CE, CSA, RCM |
| Size | 201 x 98 x 52 mm (with holster) |
| Weight | 355 g 624 g – with holster |
| Display Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
| Display Analog | 32 segments, updates 40/sec |
| Display Frequency | 19,999 counts, updates 3/sec at > 10 Hz |
| Warranty | Lifetime |
| Battery Life Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 |
| Vibration | Per MIL–PRF–28800 for a Class 2 instrument |