PVA-1500HE2 I-V Curve Tracer and 1537 Insulation Tester 2500V Kit

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
5602284  ·  HS 9030.33
PVA-1500HE2 I-V Curve Tracer and 1537 Insulation Tester 2500V Kit

Maximize Solar Efficiency with PVA-1500HE2 I-V Curve Tracer and 1537 Insulation Tester 2500V Toolkit. Enhance performance, streamline inspections, and ensure reliability.

Technical Specifications

Manufacturer part number (MPN)5602284
BrandFluke
CategoryTools
PVA-1500T2PVA-1500HE2
Voltage Range (Voc)20 to 1500V DC
Module Efficiency <19%0 to 30A DC
Module Efficiency ≥19% 0 to 10A DC0 to 30A DC
Voltage Accuracy (0 °C to 45 °C)±(0.5% ±0.25V)
Current Accuracy (0 °C to 45 °C)±(0.5% ±0.04A)
Power Accuracy (0 °C to 45 °C)±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %)
Voltage Resolution25 mV
Current Resolution2 mA
Sweep-to-sweep delay (@VOC ≤ 1350V)<9 seconds
Max number of I-V sweeps per hour (@VOC ≤ 1350V)400 sweeps/hr
Max megawatts measured per hour3.5 MW/hr
# sweeps at 18 s sweep-to-sweep delayunlimited (25 °C, 77 °F ambient) 550 (45 °C, 113 °F ambient)
# sweeps at 9s sweep-to-sweep delayunlimited (25 °C, 77 °F ambient) 330 (45 °C, 113 °F ambient)
I-V Trace Points100 or 500 (selectable)
I-V Sweep Duration0.05 to 2 seconds (typically 0.2 seconds for PV strings)
Operating Temperature Range0 °C to 45 °C, 32 °F to 113 °F
Storage Temperature Range-20 °C to 65 °C, -4 °F to 149 °F
Operating Humidity<90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Altitude2000 m max
Battery Charging Time6 hr
Battery Run Time Approx. 8 hrApprox. 7 hr
Safety and RegulatoryCAT III 1500V IEC 61010-1: Pollution Degree 2
Warning FeaturesOver-voltage, over-current, over-temperature, reverse polarity
PV Connector Staubli MC4-EVO2Banana Jacks
Charging/Charged LEDYes
In-the-field firmware update-readyYes
Interface to Tablet/LaptopWi-Fi interface between user tablet or laptop, I-V unit and SolSensor™
Weight 6.6 kg, 14.55 lb7.3 kg, 16.09 lb
43.2 cm, 1.41 ft (including test lead and strain reliefs)53.3 cm, 1.74 ft
Width21.6 cm, 8.50 in
Depth15.2 cm, 5.98 in
Voltage Range0 to 1500V DC
Current Range0 to 30A DC
Temperature0 °C to 45 °C, 32 °F to 113 °F
HumidityMaximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F)
Pollution Degree2
Lead Length152 cm, 59.84 in
Lead ColorsPositive=red, negative=black
Manufacturer (Test Leads and Alligator Clips)Staubli
Sensor TypeSilicon photodiode with corrections for temperature, spectral, and angular effects
Measurement Range100 W/m² to 1500 W/m²
Accuracy±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m²
Resolution1 W/m²
Measurement IntervalTypically, 3.5 s
Measurement Cynchronization with I-V CurveTypically, <1 s
Wireless Range (open line of sight)100 m, 328 ft
Battery Run Time>16 hr typical use
Display73.5 mm x 104 mm
Battery8 AA alkaline cells, IEC LR6
Dimensions (H x W x L)184 mm x 211 mm x 93 mm
Weight1.3 kg
Operating temperature-10 °C to +50 °C
Storage temperature-20 °C to +60 °C
Operating altitude2000 m
Storage altitude12000 m
Overvoltage categoryCAT IV 600 V
GeneralIEC 61010-1, Pollution Degree 2 IEC 61557-1
MeasurementIEC 61010-2-030: CAT IV 600 V IEC 61010-2-034: 2500 V dc
Insulation resistance measurementIEC 61557-1, IEC 61557-2
IP RatingIEC 60529 IP40
InternationalIEC 61326-1: Electromagnetic environment for portable equipments IEC 61326-2-2 CISPR 11: Group 1, Class A
Test voltage RangeResolution
250 V <200 kΩUnspecified
200 kΩ to 500 kΩ 1 kΩ5 %
0.50 MΩ to 5.00 MΩ .01 MΩ5 %
5.0 MΩ to 50.0 MΩ 0.1 MΩ5 %
50 MΩ to 500 MΩ 1 MΩ5 %
0.50 GΩ to 5.00 GΩ 0.01 GΩ5 %
5.0 GΩ to 50.0 GΩ 0.1 GΩ20 %
500 V <200 kΩUnspecified
5.0 GΩ to 10.0 GΩ 0.1 GΩ5 %
10.0 GΩ to 50.0 GΩ 0.5 GΩ20 %
50 GΩ to 100 GΩ 5 GΩ20 %
1000 V <200 kΩUnspecified
5.0 GΩ to 20.0 GΩ 0.1 GΩ5 %
20.0 GΩ to 50.0 GΩ 0.5 GΩ20 %
50 GΩ to 200 GΩ 5 GΩ20 %
2500 V <200 kΩUnspecified
0.50 MΩ to 5.00 MΩ 0.01 MΩ5 %
50 GΩ to 500 GΩ 5 GΩ20 %
RangeAccuracy
Leakage current measurement 1 nA to 2 mA±(20 % + 2 nA)
Capacitance measurement 0.01 μF to 2.00 μF±(15 % rdg + 0.03 μF)
Test voltage for insulation resistance 250 V to 2500 V±(3 % + 3 V)
Warning range>30 V
F1535>2 mA
F1537>5 mA
Function RangeResolution
VAC 0 V to 600.0 V0.1 V
VDC 0 V to 600.0 V0.1 V
Resistance 0 Ω to 600.0 Ω0.1 Ω
Resistance 600 Ω to 6000 Ω1 Ω
Resistance 6.00 kΩ to 60.00k Ω0.01 kΩ

Properties

MOQ1

Cross-References

Attached Documents