| Manufacturer part number (MPN) | 5134747 |
| Brand | Fluke |
| Category | Tools |
| FieldSense ac voltage Requires test leads | No |
| FieldSense ac voltage Range | 1000 V |
| FieldSense ac voltage Resolution | 1 V |
| FieldSense ac voltage Accuracy | ±(3 % + 3 counts) 45 Hz - 66 Hz[1] [2] |
| FieldSense ac current Requires test leads | No |
| FieldSense ac current Range | 200.0 A |
| FieldSense ac current Resolution | 0.1 A |
| FieldSense ac current Accuracy | ±(3 % + 3 counts) 45 Hz - 66 Hz |
| FieldSense frequency (Hz) Requires test leads | No |
| FieldSense frequency (Hz) Range | 45 Hz – 66 Hz |
| FieldSense frequency (Hz) Resolution | 1 Hz |
| FieldSense frequency (Hz) Accuracy | ±(1 % + 2 counts) |
| Volts ac Requires test leads | Yes |
| Volts ac Range | 1000 V |
| Volts ac Resolution | 1 V |
| Volts ac Accuracy | ±(1.5 % + 2 counts) 45 Hz - 66 Hz |
| Volts dc Requires test leads | Yes |
| Volts dc Range | 1000 V |
| Volts dc Resolution | 1 V |
| Volts dc Accuracy | ±(1 % + 2 counts) |
| Resistance Requires test leads (all ranges) | Yes |
| Resistance Range | 2000 Ω |
| Resistance Resolution | 1 Ω |
| Resistance Accuracy (all ranges) | ±(1 % + 2 counts) |
| Calibration | 1-year calibration cycle |
| Dimensions | 61 mm x 259 mm x 43 mm |
| Weight | 0.35 kg (0.78 lb) |
| Fork opening | 17.8 mm (0.7”) |
| Relative Humidity | 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F) 0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F) 0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F) |
| Temperature coefficient | 0.1 x (specified accuracy) / °C for 28 °C ( 82.4 °F) |
| Electromagnetic Compatibility | IEC/EN 61326-1: Portable |