| Manufacturer part number (MPN) | 4297115 |
| Brand | Fluke |
| Category | Tools |
| Jaw opening | 12.9 mm (0.5 in) |
| Max wire size | 1/0 THHN cable |
| Current range AC rms | 0 to 100.0 A |
| Accuracy AC current (50/60 Hz) | 3% ± 3 counts |
| AC Response | Averaging |
| Voltage range AC | 0 to 600 V |
| Accuracy AC voltage | 1.5% ± 2 counts |
| Voltage range DC | 0 to 600 V |
| Accuracy DC voltage | 1% ± 1 count |
| Resistance range | 0 to 1000 Ω |
| Continuity beeper threshold | On at 400 Ω |
| Volts indicator LED threshold | Guaranteed on by 30 V AC |
| Operating temperature | -10°C to 50°C |
| Storage temperature | -30°C to 60°C |
| Humidity (without condensation) | 0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C); 0% to 45% (40°C to 50°C) |
| Dust/water resistance | Yes |
| Operating altitude | 2000 meters max |
| Temperature coefficient | 0.1 x (specified accuracy)/°C ( 28°C) |
| Measurement Category | IEC 61010-2-032 |
| IEC61010-2-033 | CAT III 600 V, 100 A ac |
| Agency approvals | CSA, TUV |
| Maximum voltage | 600 V between any terminal and earth ground |
| Size | 30.5 x 51 x 203 mm |
| Weight | 300 g |
| Warranty | Two-years |
| Battery life | 200 hour zinc chloride, 400 hour alkaline |
| Battery type | 2 x AA |
| Low battery indicator | Yes |
| Current sensor opening | 12.9 mm |
| Calibration cycle | 1 year |
| Test leads Type | Heavy duty, flexible leads rated for 1000 V use. Field replaceable leads terminate in male shrouded banana plugs |
| Test leads Probes | One red, one black. Detachable Slim-Reach™ probe tips |
| Test leads Styles | TP1 Slim Reach™ test brobes |
| Safety | CAT IV 600 V, CAT III, 1000 V |
| Temperature range | -30°C to 650°C (-22°F to 1202°F) |
| Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
| Response time (95%) | < 300 ms (95% of reading) |
| Spectral response | 8 to 14 microns |
| Emissivity | 0.10 to 1.00 |
| Optical resolution | 12:1 (calculated at 90% energy) |
| Display resolution | 0.1°C (0.2°F) |
| Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater |
| Power | AA battery |
| Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) |
| Storage altitude | 12,000 meters above mean sea level |
| IP rating | IP 54 per IEC 60529 |
| Drop test | 3 meters |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC | EN 61326-1:2006 EN 61326-2:2006 |
| Standards and agency approval Compliance | EN/IEC 61010-1: 2001 |
| Standards and agency approval Laser safety | FDA and EN 60825-1 Class II |