| Manufacturer part number (MPN) | 2539468 |
| Brand | Fluke |
| Category | Tools |
| Electrical characteristics Nominal current in | 50 A AC rms |
| Electrical characteristics Overload | up to 100 A rms |
| Electrical characteristics Conductor position influence | < 0.5% of range at 50/60 Hz |
| Electrical characteristics Error due to adjacent conductor | ≤ 15 mA/A at 50 Hz |
| Electrical characteristics Phase shift at 2 kHz at 200 A | < ±1° |
| Electrical characteristics Frequency range | 40 Hz to 10 kHz (-3 dB) |
| Electrical characteristics Temperature coefficient | 0.015% of range / °C |
| Working voltage (see section safety) | 600 V AC rms or DC |
| Electrical characteristics Order reference | 1-phase: EP0442A |
| Accuracy Primary current 0.125 A to 2.5 A | Operating error in % of reading: ±2.5% |
| Accuracy Primary current 2.5 A to 12.5 A | Operating error in % of reading: ±1.5% |
| Accuracy Primary current 12.5 A to 25 A | Operating error in % of reading: ±0.5% |
| Accuracy Primary current 25 A to 50 A | Operating error in % of reading: ±0.5% |
| General characteristics Maximum conductor size | 15 mm diameter, bus bar 15 x 17 mm |
| General characteristics Cable length | 2 m |
| General characteristics Operating temperature range | -10°C to +55°C |
| General characteristics Storage temperature range | -20°C to +70°C |
| General characteristics Operating humidity | 15% to 85% rh (non condensing) |
| General characteristics Weight (per clamp) | 175 g |
| Reference conditions Environment temperature range | +18°C to +26°C |
| Reference conditions Humidity | 20% to 75% r.h. |
| Reference conditions Current | sinusoidal waveform, 48 to 65 Hz, distortion factor: < 1%, no DC component |
| Reference conditions Load impedance for voltage output | ≥ 1 MΩ, <100 pF |
| Safety standards | IEC/EN61010-1: 2001 |
| Safety | 600 V CAT III, pollution degree 2 |
| EMC standards | EN61326-1: 1997/A1: 1998 |
| Dimensions | 102 x 42.5 x 23.5 mm |