cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Fluke Norma 6000 Series Portable Power Analyzers

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
5125211  ·  HS 9030.84
Fluke Norma 6000 Series Portable Power Analyzers

The Fluke Norma 6000 Power Analyzer measures voltage, current, active power, reactive power, apparent power, power factor and harmonics with associated values. Lightweight, 10 hours of battery life.

Technical Specifications

Manufacturer part number (MPN)5125211
BrandFluke
CategoryTools
Inputs Norma 60033 Voltage + 3 Current
Inputs Norma 60044 Voltage + 4 Current
Sample rate200ks/s
Measurement update rate100ms, 200ms, 500ms, 1s
Dimensions (H * W * L)298mm x 215m x 96mm
Weight3.5 kg (7.7 lbs)
Display5.7 inch, TFT LCD, 640x480
Operating temperature-10 °C to +50 °C
Storage temperature-30 °C to +60 °C
Operating humidityNon-condensing (< 10 °C ) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
Operating altitude2000m
Storage altitude12000m
Ingress protectionIP 50 (Terminals mated) according to IEC 60529:
BatteryBP 291, 10.8V/5000mAh, 54Wh IEC 62133
UN38.3 Operating time10 Hours (on battery)
SafetyIEC 61010-1: Pollution Degree 2 IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMCIEC 61326-1: Industrial IEC 61326-2-2
Warranty1 Year
Communication InterfaceUSB/RS485
Dual Analyzer Synchronization ModeAble to extend to 6, 7 or 8 channels (using multiple instruments)
PC SoftwareFluke Power Analyzer software
Storage Capacity32GB
Data trend storage rateAs per display rate
Main FunctionMeter, Scope, Harmonic, Phasor, Trend
Range10 V, 100 V, 1000 V
Crest FactorCF ≤ 2
Maximum Voltage10 % overload
Input Impedance2M Ω/10pF (Typical)
Temperature Coefficient0.05 * (Spec)/k
Bandwidth1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
CMRR120 dB @ 50/60 Hz
Range 1000 V100 V
Overload capacity10 % overload
Measuring Range0.1 A, 1 A, 10 A
Range 10 A1 A
DC 0.1 + 0.20.1 + 0.5
AC (10Hz to 1kHz) 0.1+0.10.1+0.2
Voltage Range± 10 V dc, 10 % overload
Voltage Channels2
Accuracy at dc0.1 % range + 0.1 % reading
Pulse Channels3
Pulse Logic High Threshold2 V (Typical)
Pulse Logic Low Threshold0.8 V (Typical)
Maximum Pulse Frequency100 kHz
Frequency Accuracy0.05 % range + 0.05 % reading
Harmonics100 (50Hz/60Hz)
Calculation methodFFT/Interpolation

Properties

MOQ1

Cross-References

Attached Documents