| Manufacturer part number (MPN) | 5125211 |
| Brand | Fluke |
| Category | Tools |
| Inputs Norma 6003 | 3 Voltage + 3 Current |
| Inputs Norma 6004 | 4 Voltage + 4 Current |
| Sample rate | 200ks/s |
| Measurement update rate | 100ms, 200ms, 500ms, 1s |
| Dimensions (H * W * L) | 298mm x 215m x 96mm |
| Weight | 3.5 kg (7.7 lbs) |
| Display | 5.7 inch, TFT LCD, 640x480 |
| Operating temperature | -10 °C to +50 °C |
| Storage temperature | -30 °C to +60 °C |
| Operating humidity | Non-condensing (< 10 °C ) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) |
| Operating altitude | 2000m |
| Storage altitude | 12000m |
| Ingress protection | IP 50 (Terminals mated) according to IEC 60529: |
| Battery | BP 291, 10.8V/5000mAh, 54Wh IEC 62133 |
| UN38.3 Operating time | 10 Hours (on battery) |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-030: CAT IV 600V, CAT III 1000 V |
| EMC | IEC 61326-1: Industrial IEC 61326-2-2 |
| Warranty | 1 Year |
| Communication Interface | USB/RS485 |
| Dual Analyzer Synchronization Mode | Able to extend to 6, 7 or 8 channels (using multiple instruments) |
| PC Software | Fluke Power Analyzer software |
| Storage Capacity | 32GB |
| Data trend storage rate | As per display rate |
| Main Function | Meter, Scope, Harmonic, Phasor, Trend |
| Range | 10 V, 100 V, 1000 V |
| Crest Factor | CF ≤ 2 |
| Maximum Voltage | 10 % overload |
| Input Impedance | 2M Ω/10pF (Typical) |
| Temperature Coefficient | 0.05 * (Spec)/k |
| Bandwidth | 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz |
| CMRR | 120 dB @ 50/60 Hz |
| Range 1000 V | 100 V |
| Overload capacity | 10 % overload |
| Measuring Range | 0.1 A, 1 A, 10 A |
| Range 10 A | 1 A |
| DC 0.1 + 0.2 | 0.1 + 0.5 |
| AC (10Hz to 1kHz) 0.1+0.1 | 0.1+0.2 |
| Voltage Range | ± 10 V dc, 10 % overload |
| Voltage Channels | 2 |
| Accuracy at dc | 0.1 % range + 0.1 % reading |
| Pulse Channels | 3 |
| Pulse Logic High Threshold | 2 V (Typical) |
| Pulse Logic Low Threshold | 0.8 V (Typical) |
| Maximum Pulse Frequency | 100 kHz |
| Frequency Accuracy | 0.05 % range + 0.05 % reading |
| Harmonics | 100 (50Hz/60Hz) |
| Calculation method | FFT/Interpolation |