| Manufacturer part number (MPN) | 2539612 |
| Brand | Fluke |
| Category | Tools |
| Number of Phases | 1 to 3 |
| Weight | Approx. 5 kg (11 lb) |
| Size | 150 x 237 x 315 mm |
| On-board Printer | No |
| Display | Color, 5.7 in / 144 mm - 320 x 240 pixel |
| Bandwidth | DC to 3 MHz or DC to 10 MHz depending on input module |
| Basic Accuracy | 0.2%, 0.1% or 0.03% depending on input modules |
| Sampling Rate | 0.33 MHz or 1 MHz depending on input modules |
| Voltage Input Range | 0.3 V to 1000 V |
| Current Input Range (direct, not via shunt) | 0.03 mA to 20 A depending on input module |
| Memory for Configurations | 4 MB |
| Memory for Settings | 0.5 MB |
| Fast Fourier Transformation (FFT) | To the 40th harmonic |
| RS232/USB Interface | Standard |
| Digital Oscilloscope (DSO) | Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. |
| Integration function (energy) | Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. |
| Vector Display | Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. |
| Recorder | Display of average values over time for trend determination. |
| RAM data memory | Storing of sample and average values; setting of start and stop conditions. |
| Configuration | Set up the analyzer to measure and display data in the format required. |
| Working Temperature Range | 5°C to 35°C (41°F to 95°F) |
| Storage Temperature Range | -20°C to 50°C (-4°F to 122°F) |
| Housing Material | Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
| Climatic Class | KYG DIN 40040, max. 85% relative humidity, non-condensing. |
| Power supply | 85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, approx. 40 VA European plug with switch. Binding post for current available on some models. |
| Measuring Inputs | Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
| Operation | Membrane keyboard with cursor – function keys and direct functions. |
| Connections | Rear panel of the 3-phase Analyzer |
| Range | DC and 0.2 Hz to sample rate |
| Accuracy | ±0.01% of measured value (reading) |
| Options | IEEE 488.2 / 1 MBit/s |
| Electrical Safety | EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) |
| Maximum inputs | For voltage inputs Measurement range 1000 Veff, 2 kVpeak |
| Test voltage Net input | case (protective conductor): 1.5 KV AC |
| Test voltage Net connection | Measurement input: 5.4 kV AC |
| Test voltage Measurement inputs | Case: 3.3 kV AC |
| Test voltage Measurement input | input: 5.4 kV |
| Electromagnetic susceptibility Emission | IEC 61326-1, EN 50081-1, EN 55011 Class B |
| Electromagnetic susceptibility Immunity | IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |
| PP42 Accuracy | 0.2% (0.1% rd + 0.1% rg) |
| PP42 Current range | 20 A |
| PP42 Sampling rate | 341 kHz |
| PP42 Bandwidth | 3 MHz |
| PP50 Accuracy | 0.1% (0.05% rd + 0.05% rg) |
| PP50 Current range | 10 A |
| PP50 Sampling rate | 1 MHz |
| PP50 Bandwidth | 10 MHz |
| PP54 Accuracy | 0.1% (0.05% rd + 0.05% rg) |
| PP54 Current range | 10 A |
| PP54 Sampling rate | 341 kHz |
| PP54 Bandwidth | 3 MHz |
| PP64 Accuracy | 0.03% (0.02% rg + 0.01% rg) |
| PP64 Current range | 10 A |
| PP64 Sampling rate | 341 kHz |
| PP64 Bandwidth | 3 MHz |
| Continuous load (Imin) Range (Imax) | 0.3 A |
| Nominal current (calibration point) | 32 A |
| Basic accuracy at calibration point [%] | ± 0.03 |
| Basic accuracy at nominal current [%] | ± 0.03 |
| Nominal voltage drop [V] | 320 mV |
| Nominal resistance [Ohm] | 10 mΩ |
| Short time overrange (5s load 15s interval) | 100A/ 1s-5s |
| Angular accuracy [°/kHz] | ± 0.1 |
| Temperature coefficient [ppm/K] | ≤10 |
| Weight (kg / lbs) | 0.62 /1.36 |