cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
3846346
Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Buy genuine Fluke Networks Cable Fault Finder with PowerBT™ Bridge Tap Detect for open/short circuit detection—to 8,000 feet (2.4 km).

Technical Specifications

Manufacturer part number (MPN)3846346 Brand: Fluke Category: Tools Maximum Length: 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured
Representative Maximum Cable Length8,000 feet (2,438 meters): CAT-3 Twisted Pair 8,000 feet (2,438 meters): CAT-5 Twisted Pair 6,000 feet (1,830 meters): 12/2 AC Wire 3,000 feet (900 meters): RG-6/U TV Coax 1,500 feet (457 meters): RG-174/U Coax minimum Length: No minimum length (can read a bridge tap at 0 feet/meters). minimum non-zero reading is 2 feet or 1 meter
Length Accuracy"±2 feet (±0.6 m) for cables less than 10 feet (3 m) ±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m) +/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)" Distance to Bridge Tap: 0 feet to 3,200 feet (975 meters) minimum Length of Bridge Tap: 10% of the distance to the bridge tap. Dependent on the cable characteristics
Measurement RateMaximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity
VOPAdjustable from 20 to 99, saved in flash memory
Test TechnologyTime Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height
Cable TypeVirtually all two or more conductor cables
Power4 AA alkaline batteries
Reverse Battery ProtectionNo damage to the tester will occur if the batteries are installed backwards
Battery Life35 hours (typical) Low Battery Indication: LED display alternates between LO and bAtt when the battery voltage falls below 4.5v
Maximum Output Voltage4 voltage peak Maximum Isolation Voltage: 250 volts RMS Voltage Measurements: Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC High Voltage Detection: AC voltage detected to 115 volts; DC voltage detected to ±150 volts. AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display SmartTone® (5-tones) Range: 7,000 feet (2,134 meters) Toner Range: 52,800 feet (16,093 meters) Tone Injection: Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition
Impedance Range35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings
Temperature RangeOperating: 32°F to 104°F (0°C to 40°C) Storage: 32°F to 131°F (0°C to 55°C) Humidity: Operating: 20% to 80% relative humidity Storage: 0% to 100% relative humidity Operating Humidity: 80% maximum at 86°F (30°C ) 50% maximum at 104°F (40°C ) Operating Altitude: 9,843 ft max (3,000 m max) Weight: 1 lb (454 grams) Dimensions: 7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm) Safety: IEC 61010-1:2010; N10140 EMC: IEC/EN61326-1:2006 Certifications and Compliance: Conforms to relevant European Union directives Conforms to relevant Australian standards IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1

Properties

MOQ1

Cross-References