Fluke I30S AC/DC Current Clamp

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
2584935  ·  HS 9030.33
Fluke I30S AC/DC Current Clamp

The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current.

Technical Specifications

Manufacturer part number (MPN)2584935
BrandFluke
CategoryTools
Specified current range30 mA to 30 A DC, 30 mA to 20 A AC rms
Usable current range5 mA to 30 A DC, 30 mA to 20 A AC rms
Crest factor1.4 in
Output sensitivity100 mV/A
Accuracy (at +25°C)DC ±1 % of reading ±2 mA AC ± 0.5 dB of reading ±2 mA
Resolution±1 mA
Load impedance> 100 kΩ
Conductor position sensitivity±1% relative to center reading
Frequency rangeDC to 100 kHz (-0.5 dB)
Phase shift below 1 kHz< 2°
Temperature coefficient±0.01% of reading / °C
Power supply9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)300 V AC rms or DC
Maximum conductor size19 mm diameter
Output connectionSafety BNC connector, supplied with safety 4 mm adapter
Output zeroManual adjust via thumbwheel
Cable length2 m
Operating temperature range0°C to +50°C
Storage temperature range (with battery removed)-20°C to +85°C
Operating humidity15% to 85% (non-condensing)
Weight250 g
SafetyIEC 61010-1, Pollution Degree 2
EMC CompatibilityIEC 61326-1: Portable Electromagnetic Environment

Properties

MOQ1

Cross-References