The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
| Manufacturer part number (MPN) | 2584901 Brand: Fluke Category: Tools Current ranges: 30 A Output sensitivity (AC-coupled): 100 mV Load impedance: 100 kΩ minimum Accuracy: at +25°C: ±1% of range (45 Hz to 65 Hz) Linearity: 10% to 100% of range: ±0.2% of reading Noise: 8 mV AC rms (30 A) Frequency range: 10 Hz to 50 kHz (-3 dB) Phase error: < ±1° (45 Hz to 65 Hz) Position sensitivity (with cable > 25 mm from the coupling): Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range |
| External wire influence | 1% (-40 db) of external current >200 mm from head |
| External field | with cable > 200 mm from the head: ±1% of range Power supply: 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator Temperature coefficient: ±0.08% of reading per °C Working voltage: see Safety standards section: 600 V AC rms or DC Head circumference: 915 mm (36 in.) Head cable diameter: 14.3 mm (0.56 in) Head bend radius: 38.1 mm (1.5 in) Cable length (head to electronics): 2 m (6.56 ft) Output connection: 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter Operating temperature range: -20°C to +90°C (-4°F to 190°F) (head) Storage temperature range: -40°C to +105°C (-40°F to 221°F) (head) Operating humidity: 15% to 85% (non-condensing) Weight: 180 g (0.396 lb) (head) Safety standards: BS EN 61010-1: 2001 EMC standards: EN 61326: 1998 +A1, A2, and A3 Head cable length (double insulated): 610 mm or 914 mm, depending on model |
| MOQ | 1 |