cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Fluke FEV500 Fast DC EV Charging Station Analyzer

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
6008392
Fluke FEV500 Fast DC EV Charging Station Analyzer

Portable tool for testing Fast DC EV chargers—no EV needed. Combines safety, performance & data logging.

Technical Specifications

Manufacturer part number (MPN)6008392
BrandFluke
CategoryTools
CaseRugged, wheeled hardcase
Dimensions65 cm x 50.8 cm x 30 cm (25.6 in x 20 in x 11.8 in)
Weight26 kg (57 lb)
Display7-in TFT, 1024 x 600 pixels, capacitive touch (operable with PPE gloves) Ultra-bright, sunlight-readable display with up to 1,700 cd/m² Brightness adjustment with ambient light sensor
InterfaceKeys: Power on/off, Backlight
Stop Test LEDsPower, Battery Status, Charging
BatteryLithium-ion; 10.8 V, 6.8 Ah, 73.44 Wh (customer replaceable)
Runtime10 hours (battery recharges during test)
Charging TimeTypically 3 hours with USB-C PD 65 W charger
Backup DurationUp to 6 months before recharge
Wireless ConnectivityIntegrated Wi-Fi (802.11b/g/n) and Bluetooth 5.2 module TX/RX Frequency Range: 2400 MHz to 2483.5 MHz Transmit Operating Power: < 100mW Encryption: WPA2-AES (WiFi), AES-CCM (Bluetooth) (Activation subject to firmware support. Refer to release notes for availability.)
USB-CUSB 2.0 high-speed for data download to PC-software TruTest™ and calibration Charging battery with USB-C power adapter PD 2.0 or higher with 9V 1.8 A USB-C flash drive support for firmware updates Max supply current: 900 mA
GNSSGlobal navigation satellite receiver with internal antenna for time synchronization
Fuse11 A (not customer replaceable)
WarrantyMain unit: 2 years Battery and accessories: 1 year
Operating Temperature-20 °C to +50 °C (-4 °F to +122 °F)
Battery Charging Temperature0 °C to +45 °C (32 °F to +113 °F)
Storage Temperature-20 °C to +60 °C (-4 °F to +140 °F); Recommended: 0 °C to +30 °C
Operating Humidity≤100% up to 30 °C; 55% at 40 °C; 35% at 50 °C
Operating AltitudeUp to 3000 m
Storage AltitudeUp to 12,000 m
VibrationIEC 60721-3-3 / 3M2
Drop Test0.5 m (visual defects allowed)
Ingress Protection (lid closed)IP54
Ingress Protection (lid opened)IP40 (protected against objects ≥1 mm) Air-cooling plenum: IP20 (protected against objects ≥12.5 mm) No protection against water ingress
Safety StandardIEC 61010-1, Pollution Degree 2 IEC 61010-2-034
Performed TestsCCS Low-Level Communication and SLAC Test, Continuity Test, Insulation Resistance Test, Load Test (including Cable Check Voltage Measurement), IMD Test, Residual Voltage Test
MeasurementTest probe to PE pin of CCS 1/2 socket
Open-Loop VoltageMax 5 V
Test CurrentMax 10 A (up to 0.2 Ω)
Test MethodDC test with alternating polarity
Live Circuit DetectionInhibits test if test probe voltage > 60 V
Test Probe ZeroingSelect ZERO in user interface to zero the test probe resistance.
StandardIEC61557-4
Test Voltage RLO RangeResolution
2 Ω<1Ω: 0.1 mΩ ≥1Ω: 0.0001Ω
MeasurementsInsulation Resistance DC+ to PE and DC- to PE
Test VoltageMax EVSE Voltage ≤ 500 V: 500 V +10% / -0% Max EVSE Voltage > 500 V: 1000 V +10% / -0%
Max Short Circuit Current2 mA
Test Voltage RISO RangeResolution
500 V 10 kΩ to 20 MΩ0.01 MΩ
1000 V 10 kΩ to 20 MΩ0.01 MΩ
ParametersVoltage CP high, Voltage CP low, Frequency, Duty Cycle
Simulation of statesA, B, C, D, E (simulation and validation)
Digital ProtocolDIN SPEC 70121, ISO 15118
Parameter RangeResolution
CP High
CP Low -15 V to +15 V0.01 V
Frequency DC, 900 to 1100 Hz1 Hz
Duty Cycle 2 to 98 %0.10%
SLAC 0 dB to 20 dB1 dB
PP Resistor 50.0 to 499.9 Ω0.1 Ω
PP Resistor 500 to 5000 Ω1 Ω
Voltage 1000 V0.1 V
Current 10 A0.01 A
Power 0 to 3.75 kW0.001 kW
Auto-TestNo trip test, trip test Test Resistor no trip test: 250 kΩ (DC+ to PE) Test Resistor trip test: 95 kΩ (max. EVSE Voltage >500 V dc), 45 kΩ (max. EVSE Voltage ≤500 V dc) (DC- to PE) Duration: max 15 s for each test
Test Resistor Range19.5 kΩ to 3 MΩ, 256 values

Properties

MOQ1

Cross-References

Attached Documents