Fluke Calibration 9143 Field Metrology Well

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
3054547  ·  HS 9031.80
Fluke Calibration 9143 Field Metrology Well

Fluke 9143 Field Metrology Wells: ✅ High performance. ✅ Free shipping at fluke.com. ✅ Unmatched value. ✅ Official Fluke. Learn more

Technical Specifications

Manufacturer part number (MPN)3054547
BrandFluke
CategoryTools
Temperature range at 23°C33°C to 350°C (91°F to 662°F)
Display accuracy±0.2°C Full Range
Stability±0.02°C at 33°C ±0.02°C at 200°C ±0.03°C at 350°C
Axial uniformity at 40 mm (1.6 in)±0.04°C at 33°C ±0.1°C at 200°C ±0.2°C at 350°C
Radial uniformity±0.01°C at 33°C ±0.015°C at 200°C ±0.02°C at 350°C
Hysteresis0.03
Operating conditions0°C to 50°C, 0% to 90% RH (non-condensing)
Immersion (well) depth150 mm (5.9 in)
Insert OD25.3 mm (1.00 in)
Heating time5 min: 33°C to 350°C
Cooling time32 min: 350°C to 33°C 14 min: 350°C to 100°C
Resolution0.01°
DisplayLCD, °C or °F user-selectable
Size (H x W x D)290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight7.3 kg (16 lb)
Power requirements100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Computer interfaceRS-232 interface
CalibrationAccredited calibration included
AutomationUse the 1586A Super-DAQ to automate temperature sensor calibration
Reference resistance range0 ohms to 400 ohms
Reference resistance accuracy20 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizationsITS-90, CVD, IEC-751, Resistance
Reference measurement capability4-wire
Reference probe connection6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracyNI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range0 ohms to 400 ohms
RTD resistance accuracy‡0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizationsPT-100 (385),(JIS),(3926), NI-120, Resistance
RTD measurement capability4-wire RTD (2-,3-wire RTD w\ Jumpers only)
RTD connection4 terminal input
Built-in TC thermometer readout accuracyType J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
TC millivolt range–10 mV to 75 mV
Voltage accuracy0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy±0.35°C (ambient of 13°C to 33°C)
TC connectionSmall connectors
Built-in mA readout accuracy0.02% of reading + 2 mV
mA rangeCal 4-22 mA, Spec 4-24 mA
mA connection2 terminal input
Loop power function24 V DC loop power