cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Fluke 87V MAX True-rms Digital Multimeter

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
5140033  ·  HS 9030.33
Fluke 87V MAX True-rms Digital Multimeter

The Fluke 87V MAX multimeter contains all the trusted features of the popular 87V, plus IP67 Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster and more.

Technical Specifications

Manufacturer part number (MPN)5140033
BrandFluke
CategoryTools
Fluke 87V MAX True-rms Digital MultimeterFluke 87V Industrial Multimeter
IP rating IP 67IP 30
Battery life 800 hours400 hours
Drop test 4 meters3 meters
Backlit keypad YesNo
DC Voltage Range0.1 mV to 1000 V
DC Voltage Accuracy±(0.05% + 1)
DC Voltage Maximum resolution0.1 mV
AC Voltage Range0.1 mV to 1000 V
AC Voltage Accuracy±(0.7% + 4) true-rms
AC Voltage AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
AC Voltage Maximum resolution0.1 mV
DC Current Range0.1 μA to 10 A (20 A for 30 seconds maximum)
DC Current Amps accuracy±(0.2% + 2)
DC Current Maximum resolution0.1 µA
AC Current Range0.1 μA to 10 A (20 A for 30 seconds maximum)
AC Current Amps accuracy±(1.0% + 2) true-rms
AC Current Maximum resolution0.1 µA
Resistance Range0.1 Ω to 50 MΩ
Resistance Accuracy±(0.2% + 1)
Resistance Maximum resolution0.1 Ω
Capacitance Range0.01 nF to 9999 μF
Capacitance Accuracy±(1% + 2)
Capacitance Maximum resolution0.01 nF
Frequency Range0.5 Hz to 199.99 kHz
Frequency Accuracy±(0.005% + 1)
Frequency Maximum resolution0.01 Hz
Duty cycle Maximum duty cycle99.9%
Duty cycle Accuracy±(0.2% per kHz + 0.1%)
Duty cycle Maximum resolution0.1%
Temperature measurement range–200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe
80 BK temperature probe–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
Conductance Maximum conductance60.00 nS
Conductance Accuracy±(1.0% + 10)
Conductance Maximum resolution0.01 nS
Diode test Range2 V
Diode test Resolution0.001V
Diode test Accuracy±(1% + 1)
Diagnostics and data storage Peak Min/Max250 μS
Diagnostics and data storage Min/Max/AvgYes
Diagnostics and data storage Reading hold/Auto (Touch) HoldYes
Diagnostics and data storage Relative referenceYes
Display Digital6000 counts updates 4/second 19,999 counts in high–resolution mode
Display Analog bar graph32 segments, updates 40/second
Display BacklightTwo level
Low pass filter (VFD measurements)Yes
Input Alert™Yes
Safety ratingIEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
Agency approvalsCE, CSA
IP ratingIEC 60529: IP67
PowerThree AA batteries. 800 hours typical, without backlight
Size6.0 x 10.1 x 21.5 cm (with holster)
Weight698.5 g (with holster)
WarrantyLimited lifetime
Operating temperature-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
Storage temperature-40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C)
Operating altitude2000 m

Properties

MOQ1

Cross-References