| Manufacturer part number (MPN) | 6120945 |
| Brand | Fluke |
| Category | Tools |
| Drop test | 1.2 m (4 ft) |
| Dimensions | 267 mm L x 171 mm H x 35 mm D 10 33/64" x 6 47/64" x 1 3/8" |
| Weight | 930 g/2.1 lbs |
| CE conformity | Refer to the CE compliance certificate |
| Carrying case Dimensions | 595 x 355 x 115 mm (23 1/2" x 14" x 4 1/2") |
| Type 6-axis | 2 planes (4 displacement axes and 2 angles) |
| Measurement Optical range | 14 x 14 mm (0.55 x 0.55 in.) |
| Measurement Area | Unlimited, dynamically extendible |
| Measurement Resolution | 1 μm (0.04 mil); Angular 10 μRad |
| Measurement Error | < 2% |
| Measurement Transmitted rate | Approx. 20 Hz |
| Inclinometer Resolution | 0.1° |
| Inclinometer Error | Roll +-1°; Pitch +- 3° |
| LED indicators | 1 LED for laser adjustment, battery and charge status; 1 LED for BT communication |
| Power supply Battery | Lithium-Ion rechargeable battery 3.7 V, 4.7 Wh |
| Power supply Operating time | 30 hours (continuous use) |
| Power supply Charging time | 2.5 h for up to 80%; 4 h for up to 100% |
| Power supply Charging | USB-C |
| External interface | Integrated low power 2.4 GHz Radio (BT LE); USB 2.0 Full Speed |
| Radio transmission distance | Up to 50 m (160 ft) direct line of sight |
| Environmental protection IP 65 | Dustproof and water jets resistant, shockproof |
| Environmental protection Relative humidity | 10% to 90% |
| Ambient light protection | Optical and active electronic digital compensation |
| Temperature range Operation | -10°C to 50°C (14°F to 122°F) |
| Temperature range Charging | 0°C to 35°C (32°F to 95°F) |
| Temperature range Storage | -20°C to 50°C (-4°F to 122°F) |
| Type | Semiconductor laser diode |
| Laser Power | < 1 mW |
| Laser Divergence | 0.3 mrad |
| Laser Wavelength | 630-640 nm (red, visible) |
| Laser Separation distance | Up to 10 m |
| Laser Adjustment | No |
| Laser Safety class | Class 2 according to IEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019 |
| Safety precaution | Do not look into laser beam |