| Manufacturer part number (MPN) | 4777186 |
| Brand | Fluke |
| Category | Tools |
| Measurement function Range and resolution | Best accuracy (% of reading + LSD) |
| V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V | 0.1% + 1 |
| V ac (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V | 0.7% + 2 |
| mA dc 30.000 mA | .05% + 2 |
| A dc 1.000 A (0.440 A continuous) | 0.2% + 2 |
| A ac 1.000 A (0.440 A continuous) | 1% + 2 |
| 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M | 0.2% + 1 |
| 199.99 Hz, 1999.9 Hz, 19.999 kHz | .005% + 1 |
| Diode test 2.000 V (shows diode voltage drop) | 2% + 1 |
| Continuity | Beeps for resistance |
| Output function Range and resolution | Drive capability |
| Current adjustment modes | Manual: Coarse, Fine, 25% and 100% step |
| Maximum voltage applied between any jack and earth ground | 1000 V RMS |
| Storage temperature | -40 °C to 60 °C |
| Operating temperature | -20 °C to 55 °C |
| Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures 28 °C) |
| Relative humidity | 95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C |
| Vibration | Random, 2 g, 5-500 Hz |
| Shock | 1 meter drop test |
| Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
| Size (HxWxL) | 50 x 100 x 203 mm (1.97 x 3.94 x 8.00 in) |
| Weight | 600 g (1.3 lbs) |
| Battery | Four AA alkaline batteries |
| Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
| Warranty | Three years |