| Manufacturer part number (MPN) | 4296083 |
| Brand | Fluke |
| Category | Tools |
| Temperature range | -30°C to 650°C (-22°F to 1202°F) |
| Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
| Response time (95%) | < 300 ms (95% of reading) |
| Spectral response | 8 to 14 microns |
| Emissivity | 0.10 to 1.00 |
| Optical resolution | 12:1 (calculated at 90% energy) |
| Display resolution | 0.1°C (0.2°F) |
| Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater |
| Power | AA battery |
| Battery life | 8 hours with laser and backlight on |
| Weight | 255 g (8.99 oz) |
| Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
| Operating temperature | 0°C to 50°C (32°F to 122°F) |
| Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) |
| Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) |
| Operating altitude | 2000 meters above mean sea level |
| Storage altitude | 12,000 meters above mean sea level |
| IP rating | IP 54 per IEC 60529 |
| Drop test | 3 meters |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC | EN 61326-1:2006 EN 61326-2:2006 |
| Standards and agency approval Compliance | EN/IEC 61010-1: 2001 |
| Standards and agency approval Laser safety | FDA and EN 60825-1 Class II |
| Temperature Operating | -10°C to 55°C (14°F to 131°F) |
| Temperature Storage | -30°C to 60°C (-22°F to 140°F) |
| Relative humidity | 0°C to 30°C (32°F to 86°F): 90% |
| Altitude Operating | 2,000 m (approx. 6,561.6 ft) |
| Altitude Storage | 10,000 m (approx. 32,808.4 ft) |
| Battery type/life | AAA (2); 40 hours |
| Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument |
| Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV |
| AC bandwidth | 45 Hz to 66 Hz |
| Maximum working voltage | 1000 V AC/DC |
| Maximum measurable voltage | 600 V AC/DC |
| Duty cycle | Indefinitely for voltages up to 240 V |
| Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC ±35% |
| LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V |
| LED voltage indication levels for Canadian version | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V |
| LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% |
| LCD accuracy on T+PRO only AC voltage | ±(3% rdg + 2 digits) |
| LCD accuracy on T+PRO only DC voltage | ±(2% rdg + 2 digits) |
| LCD accuracy on T+PRO only Resistance | ±(5% rdg + 3 digits) |
| LCD resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V 0.01 kΩ for resistance measurement (For T+PRO Only) |
| GFCI test current | 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA |
| Standard input test current | < 5 mA |
| Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm) |
| Operating principle | Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |
| Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |
| Detector tip style | Blade or round, depending on model |
| Light source | One high intensity red LED |
| Agency approvals | c CSA us, CE, C-Tick |
| Safety rating | 1000 V, CAT IV |
| Operating humidity ranges 0% to 95% | (0°C to 30°C) |
| Operating humidity ranges 0% to 75% | (30°C to 40°C) |
| Operating humidity ranges 0% to 45% | (40°C to 55°C) |
| Batteries | 2 AAA alkaline batteries included |