| Manufacturer part number (MPN) | 4296052 |
| Brand | Fluke |
| Category | Tools |
| Typical Measuring Tolerance ¹ | ±2.0 mm ³ |
| Maximum Measuring Tolerance ² | ±3.0 mm ³ |
| Range At Leica Target Plate GZM26 | 50 m / 165 ft |
| Typical Range ¹ | 40 m / 130 ft |
| Range At Unfavorable Condition 4 | 35 m / 115 ft |
| Smallest Unit Displayed | 1 mm / 1/16 in |
| Ø Laser Point At Distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
| Measuring Tolerance To Laser Beam 5 | No |
| Measuring Tolerance To Housing 5 | No |
| Range | No |
| Laser Class | 2 |
| Laser Type | 635 nm, < 1 mW |
| Protection Class | IP40 |
| Automatic Laser Off | After 90 seconds |
| Automatic Power Off | After 180 seconds |
| Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
| Size (L x W x D) | 116 x 53 x 33 mm |
| Weight (with batteries) | 113 g |
| Maximum Altitude | 3000 m |
| Maximum Relative Humidity | 85% at 20 °F to 120 °F (-7 °C to 50 °C) |
| Safety | IEC Standard No. 61010-1:2001 |
| EMC | EN 55022:2010 |
| Temperature Range | -30 °C to 650 °C (-22 °F to 1202 °F) |
| Accuracy | ±1.0 °C or ±1.0% of reading, whichever is greater |
| Response Time (95%) Fluke 62 MAX+ | < 300 ms (95% of reading) |
| Response Time (95%) Spectral response | 8 to 14 microns |
| Response Time (95%) Emissivity | 0.10 to 1.00 |
| Optical Resolution | 12:1 (calculated at 90% energy) |
| Display Resolution | 0.1 °C (0.2 °F) |
| Repeatability Of Readings | ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater |
| Power | AA battery |
| Battery Life | 8 hours with laser and backlight on |
| Weight | 255 g (8.99 oz) |
| Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| Storage Temperature (Without Battery) | -20 °C to 60 °C (-4 °F to 140 °F) |
| Operating Humidity | 10% to 90% RH non-condensing at 30 °C (86 °F) |
| Operating Altitude | 2000 meters above mean sea level |
| Storage Altitude | 12,000 meters above mean sea level |
| IP Rating | IP 54 per IEC 60529 |
| Drop Test | 3 meters |
| Vibration And Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz |
| Compliance | EN/IEC 61010-1: 2001 |
| Laser Safety | FDA and EN 60825-1 Class II |